What does Indoor CO2 and the Cross Draught conclude, in numbers, about “1400 ppm in the Meeting Room: Three Controlled Exposure Experiments and Decision Scores”?

Answer: Chapter 1 recomputes the table of Allen and colleagues, confirms the fall of 0.503, and shows that giving the null half the weight shrinks the predicted fall at 1400 ppm from 0.446 to 0.223.

Scope of the numbers: Marked boxes separate published evidence, runnable Python calculations (21 programs), classical sources and the author's hypotheses.

中文版

Data table

The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 0.223, 0.446, 1400

predicted fall of the average score, relative to 550 ppm
reading700 945 1000 1400 2500
A Allen reported0.079 0.207 0.236 0.446 1.000
B p11 refit0.084 0.221 0.252 0.476 1.000
C Zhang null0.000 0.000 0.000 0.000 0.000
weight on null fall at 1400 (A) fall at 1400 (B)
0.000.446 0.476
0.250.335 0.357
0.500.223 0.238
0.750.112 0.119
0.900.045 0.048
Satish 2012, 2500 ppm7 scales, raw ratios 0.06 to 0.56
null weight that brings A below a 0.10 fall0.776
Show the full program
# Chapter 1. p12: three dose-response readings of pure CO2 at 1400 ppm.
# Readings: (A) Allen 2016 reported slope, 21 % of the average score per
# 400 ppm; (B) the linear fit of p11, 0.224 per 400 ppm; (C) the null of
# Zhang et al. 2017, no effect of pure CO2 up to 3000 ppm. A weight w on
# the null gives a mixture; the sweep shows how fast the headline shrinks.
# The mixture weights are illustrative, not a meta-analysis.
# 三种剂量反应读法与零效应权重的敏感度扫描;权重为示意。
import math

BASE = 550.0      # ppm, the Green+ level of Allen 2016
TARGET = 1400.0   # ppm, the high CO2 day
SLOPES = (("A Allen reported", 0.21), ("B p11 refit", 0.224))


def drop(slope_per_400, c):
    return min(1.0, slope_per_400 * (c - BASE) / 400.0)


if __name__ == "__main__":
    print("predicted fall of the average score, relative to 550 ppm")
    print("reading            700    945   1000   1400   2500")
    for name, k in SLOPES:
        row = "".join("{:7.3f}".format(drop(k, c))
                      for c in (700, 945, 1000, 1400, 2500))
        print("{:16s}{}".format(name, row))
    print("{:16s}{}".format("C Zhang null", "{:7.3f}".format(0.0) * 5))
    print("weight on null   fall at 1400 (A)   fall at 1400 (B)")
    for w in (0.0, 0.25, 0.5, 0.75, 0.9):
        fa = math.fsum([(1 - w) * drop(0.21, TARGET), w * 0.0])
        fb = math.fsum([(1 - w) * drop(0.224, TARGET), w * 0.0])
        print("{:12.2f}{:17.3f}{:19.3f}".format(w, fa, fb))
    print("Satish 2012, 2500 ppm: 7 scales, raw ratios 0.06 to 0.56")
    w10 = 1 - 0.10 / drop(0.21, TARGET)
    print("null weight that brings A below a 0.10 fall: {:.3f}".format(w10))

Single source and citation

Fan, Y. (2026). Indoor CO2 and Cognitive Decline, Bernoulli Cross-Ventilation and an Engineering Re-reading of 'Storing Wind, Gathering Qi' (Version 1.0.0), Chapter 1: 1400 ppm in the Meeting Room: Three Controlled Exposure Experiments and Decision Scores. 5D Library. DOI pending

DOI pending · monograph page goes live after publication · 5DL-B-194 · v1.0.0 · CC-BY-NC-ND-4.0

BibTeX
@book{fan2026194,
  author    = {Fan, Yafu},
  title     = {Indoor CO2 and Cognitive Decline, Bernoulli Cross-Ventilation and an Engineering Re-reading of 'Storing Wind, Gathering Qi'},
  year      = {2026},
  publisher = {5D Library},
  edition   = {1.0.0},
  note      = {DOI pending}
}

Other chapter answers in this book