What does Indoor CO2 and the Cross Draught conclude, in numbers, about “The Clean Air Delivery Rate of a Pot Plant: the Arithmetic of a Hundred Pots per Square Metre”?
Answer: Chapter 3 converts plant-chamber data into clean air delivery rates: a room with one air change per hour needs 117.4 pots per square metre.
Scope of the numbers: Marked boxes separate published evidence, runnable Python calculations (21 programs), classical sources and the author's hypotheses.
Data table
The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. printed values that match the answer: 117.4
| chamber 0.25 m^3: k_obs 0.30/h, k_0 0.21/h | |
| half-life in chamber 2.3 h, plant CADR 0.0225 m^3/h | |
| same plant in a 54 m^3 room adds 0.00042 air changes/h | |
| CADR per plant plants/m2 at 0.5 ACH | 1.0 ACH 2.0 ACH |
| 0.0027 | 500.0 1000.0 2000.0 |
| 0.0075 | 180.0 360.0 720.0 |
| 0.0230 | 58.7 117.4 234.8 |
| 0.0750 | 18.0 36.0 72.0 |
| 0.2700 | 5.0 10.0 20.0 |
| a 20 m^2 room at 1 ACH, median plant | 2348 pots |
Show the full program
# Chapter 3. p31: from a sealed-chamber plant test to plants per m^2.
# Model (after Cummings and Waring 2020): a chamber of volume Vc shows a
# first-order VOC decay k_obs; minus the empty-chamber loss k_0 gives the
# plant's clean air delivery rate CADR = Vc (k_obs - k_0). A room of
# floor area A and height H at n air changes per hour already delivers
# n H A m^3/h of clean air; matching it needs n H / CADR plants per m^2.
# Median single-plant CADR 0.023 m^3/h is from that review; the chamber
# example and the CADR spread are illustrative.
# 密闭舱衰减换算为洁净空气输送率,再换算为每平方米所需盆数。
H = 2.7 # m, ceiling height
def cadr(vc, k_obs, k0):
return vc * (k_obs - k0)
def plants_per_m2(ach, cadr_one, h=H):
return ach * h / cadr_one
if __name__ == "__main__":
vc, k_obs, k0 = 0.25, 0.30, 0.21
c = cadr(vc, k_obs, k0)
print("chamber {:.2f} m^3: k_obs {:.2f}/h, k_0 {:.2f}/h".format(
vc, k_obs, k0))
print("half-life in chamber {:.1f} h, plant CADR {:.4f} m^3/h".format(
0.6931 / k_obs, c))
print("same plant in a 54 m^3 room adds {:.5f} air changes/h".format(
c / 54.0))
print("CADR per plant plants/m2 at 0.5 ACH 1.0 ACH 2.0 ACH")
for one in (0.0027, 0.0075, 0.023, 0.075, 0.27):
print("{:14.4f} {:22.1f} {:9.1f} {:9.1f}".format(
one, plants_per_m2(0.5, one), plants_per_m2(1.0, one),
plants_per_m2(2.0, one)))
n20 = 20 * plants_per_m2(1.0, 0.023)
print("a 20 m^2 room at 1 ACH, median plant: {:.0f} pots".format(n20))Single source and citation
Fan, Y. (2026). Indoor CO2 and Cognitive Decline, Bernoulli Cross-Ventilation and an Engineering Re-reading of 'Storing Wind, Gathering Qi' (Version 1.0.0), Chapter 3: The Clean Air Delivery Rate of a Pot Plant: the Arithmetic of a Hundred Pots per Square Metre. 5D Library. DOI pending
DOI pending · monograph page goes live after publication · 5DL-B-194 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026194,
author = {Fan, Yafu},
title = {Indoor CO2 and Cognitive Decline, Bernoulli Cross-Ventilation and an Engineering Re-reading of 'Storing Wind, Gathering Qi'},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
note = {DOI pending}
}Other chapter answers in this book
- Chapter 1 · 1400 ppm in the Meeting Room: Three Controlled Exposure Experiments and Decision Scores
- Chapter 2 · The Stirred Tank: How an Eight-Person Meeting Room Climbs to 1400 ppm
- Chapter 4 · Bernoulli's Orifice and the Cross Draught: Wind Pressure, Stack Pressure and Openings in Series
- Chapter 5 · Pulse Ventilation and Dynamic Programming: a Window Schedule inside a Sawtooth
- Chapter 6 · A Concentration Is Not a Dose: Confounding, Rebreathed Air and Sensor Error
- Chapter 7 · Classical Sources East and West: Storing Wind and Gathering Qi in the Zangshu, and the Eight Winds of Vitruvius
- Chapter 8 · The Empirical Loop: Studio Ventilation Schedules, Reception-Room Closing Rates and a Plan for Refutation