What does Indoor CO2 and the Cross Draught conclude, in numbers, about “Classical Sources East and West: Storing Wind and Gathering Qi in the Zangshu, and the Eight Winds of Vitruvius”?
Answer: Chapter 7 examines "qi scatters on the wind" in the Zangshu traditionally attributed to Guo Pu and the eight winds of Vitruvius; a fully sheltered room keeps only 0.317 of the open-site flow.
Scope of the numbers: Marked boxes separate published evidence, runnable Python calculations (21 programs), classical sources and the author's hypotheses.
Data table
The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 0.317
| shelter s | local wind | Q m3/h | ACH | steady ppm | tau min |
| 1.00 | 2.00 | 752 | 8.9 | 619 | 6.7 |
| 0.70 | 1.40 | 556 | 6.6 | 689 | 9.1 |
| 0.50 | 1.00 | 433 | 5.1 | 766 | 11.7 |
| 0.30 | 0.60 | 323 | 3.8 | 883 | 15.6 |
| 0.15 | 0.30 | 262 | 3.1 | 991 | 19.2 |
| 0.00 | 0.00 | 238 | 2.8 | 1048 | 21.1 |
| full shelter keeps 0.317 of the open-site flow |
Show the full program
# Chapter 7. p71: "qi scatters on the wind": shelter as a ventilation knob.
# Model: a shelter factor s (local wind / open-site wind) scales the wind
# term of p41; the stack term of p42 (dT 3 K, h 1.5 m) is untouched. The
# room is the 84 m^3 meeting room of p21 with eight people and openings
# of 0.25 m^2 on two sides; open-site wind 2 m/s. "Gathering" is read as
# the steady CO2 excess and as the time constant of any indoor release.
# Shelter factors are illustrative, not measurements of any real site.
# 把“藏风”写成遮蔽系数 s,看它如何同时“聚”住人呼出的 CO2;示意参数。
import math
CD, DCP, G9, V, C0 = 0.61, 0.8, 9.81, 84.0, 420.0
GEN = 8 * 0.0052e-3 * 3600
AE = 0.25 / math.sqrt(2.0)
U0 = 2.0
def q_total(s, dt=3.0, h=1.5):
qw = CD * AE * s * U0 * math.sqrt(DCP)
qs = CD * AE * math.sqrt(2.0 * G9 * h * dt / 293.0)
return 3600 * math.hypot(qw, qs) + 0.3 * V
if __name__ == "__main__":
print("shelter s local wind Q m3/h ACH steady ppm tau min")
for s in (1.0, 0.7, 0.5, 0.3, 0.15, 0.0):
q = q_total(s)
ach = q / V
print("{:9.2f} {:11.2f} {:8.0f} {:5.1f} {:11.0f} {:8.1f}".format(
s, s * U0, q, ach, C0 + 1e6 * GEN / q, 60.0 / ach))
r = q_total(0.0) / q_total(1.0)
print("full shelter keeps {:.3f} of the open-site flow".format(r))Single source and citation
Fan, Y. (2026). Indoor CO2 and Cognitive Decline, Bernoulli Cross-Ventilation and an Engineering Re-reading of 'Storing Wind, Gathering Qi' (Version 1.0.0), Chapter 7: Classical Sources East and West: Storing Wind and Gathering Qi in the Zangshu, and the Eight Winds of Vitruvius. 5D Library. DOI pending
DOI pending · monograph page goes live after publication · 5DL-B-194 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026194,
author = {Fan, Yafu},
title = {Indoor CO2 and Cognitive Decline, Bernoulli Cross-Ventilation and an Engineering Re-reading of 'Storing Wind, Gathering Qi'},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
note = {DOI pending}
}Other chapter answers in this book
- Chapter 1 · 1400 ppm in the Meeting Room: Three Controlled Exposure Experiments and Decision Scores
- Chapter 2 · The Stirred Tank: How an Eight-Person Meeting Room Climbs to 1400 ppm
- Chapter 3 · The Clean Air Delivery Rate of a Pot Plant: the Arithmetic of a Hundred Pots per Square Metre
- Chapter 4 · Bernoulli's Orifice and the Cross Draught: Wind Pressure, Stack Pressure and Openings in Series
- Chapter 5 · Pulse Ventilation and Dynamic Programming: a Window Schedule inside a Sawtooth
- Chapter 6 · A Concentration Is Not a Dose: Confounding, Rebreathed Air and Sensor Error
- Chapter 8 · The Empirical Loop: Studio Ventilation Schedules, Reception-Room Closing Rates and a Plan for Refutation