Indoor CO2 and Cognitive Decline, Bernoulli Cross-Ventilation and an Engineering Re-reading of 'Storing Wind, Gathering Qi': chapter answers
This book tests a counterintuitive claim: the roughly 1400 ppm of carbon dioxide common in meeting rooms has gone with a marked fall in decision-test scores in controlled exposure experiments, while pot plants do almost nothing for indoor air, so that matching the air exchange of an ordinary room would take something like a hundred pots per square metre. The book writes the claim as runnable arithmetic and corrects the wording of its original plan against the primary literature: the "half" of Allen and colleagues in 2016 is measured against the two best days, the high carbon dioxide day and t…
DOI pending · monograph page goes live after publication · 5DL-B-194 · 中文版
- Chapter 1 · 1400 ppm in the Meeting Room: Three Controlled Exposure Experiments and Decision Scores
Chapter 1 recomputes the table of Allen and colleagues, confirms the fall of 0.503, and shows that giving the null half the weight shrinks the predicted fall at 1400 ppm from 0.446 to 0.223. - Chapter 2 · The Stirred Tank: How an Eight-Person Meeting Room Climbs to 1400 ppm
Chapter 2 uses the stirred-tank equation to show that an eight-person meeting room with 0.5 air changes per hour of infiltration crosses 1000 ppm after 21.3 minutes and 1400 ppm after 38.6. - Chapter 3 · The Clean Air Delivery Rate of a Pot Plant: the Arithmetic of a Hundred Pots per Square Metre
Chapter 3 converts plant-chamber data into clean air delivery rates: a room with one air change per hour needs 117.4 pots per square metre. - Chapter 4 · Bernoulli's Orifice and the Cross Draught: Wind Pressure, Stack Pressure and Openings in Series
Chapter 4 uses Bernoulli's orifice formula to show that a cross draught of 694 cubic metres per hour is driven by only 1.92 pascals. - Chapter 5 · Pulse Ventilation and Dynamic Programming: a Window Schedule inside a Sawtooth
Chapter 5 finds the lowest-cost window schedule by dynamic programming: a two-hour meeting held below 1000 ppm needs at least 35 open minutes and loses 2.34 kilowatt-hours of heat in winter, against 7.01 with the window… - Chapter 6 · A Concentration Is Not a Dose: Confounding, Rebreathed Air and Sensor Error
Chapter 6 shows that field data cannot separate carbon dioxide from bioeffluents, and reads 1400 ppm as a rebreathed fraction of 0.0258. - Chapter 7 · Classical Sources East and West: Storing Wind and Gathering Qi in the Zangshu, and the Eight Winds of Vitruvius
Chapter 7 examines "qi scatters on the wind" in the Zangshu traditionally attributed to Guo Pu and the eight winds of Vitruvius; a fully sheltered room keeps only 0.317 of the open-site flow. - Chapter 8 · The Empirical Loop: Studio Ventilation Schedules, Reception-Room Closing Rates and a Plan for Refutation
Chapter 8 gives the empirical loop for studios, live-stream rooms and reception rooms, the distilled Ventilation Scheduler (the demonstration live-stream room is open for 0.243 of the time) and a pre-registered 32-perso…