What does Indoor CO2 and the Cross Draught conclude, in numbers, about “A Concentration Is Not a Dose: Confounding, Rebreathed Air and Sensor Error”?

Answer: Chapter 6 shows that field data cannot separate carbon dioxide from bioeffluents, and reads 1400 ppm as a rebreathed fraction of 0.0258.

Scope of the numbers: Marked boxes separate published evidence, runnable Python calculations (21 programs), classical sources and the author's hypotheses.

中文版

Data table

The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 0.0258, 1400

CO2 ppmrebreathedair in 1 LP q=5P q=20P q=100
6000.00474.7 mL0.00590.02340.1117
8000.010010.0 mL0.01240.04880.2212
10000.015315.3 mL0.01890.07350.3172
14000.025825.8 mL0.03170.12100.4752
20000.041641.6 mL0.05060.18770.6464
30000.067967.9 mL0.08140.28790.8168
risk ratio 1400 vs 800 ppm at q = 20: 2.48
excess ratio (1400-420)/(800-420): 2.58
Show the full program
# Chapter 6. p62: CO2 as a meter of rebreathed air (Rudnick and Milton).
# Model: rebreathed fraction f = (C - C0) / Ca with exhaled-breath CO2
# Ca = 38000 ppm; the steady-state Wells-Riley form of Rudnick and Milton
# 2003 gives the chance that one susceptible person is infected,
#   P = 1 - exp(-f I q t / n),
# with I infectors, q quanta per hour, t hours, n people. One infector,
# n = 8, t = 2 h; the quanta rates are illustrative, not disease data.
# 以 CO2 读出“再呼吸空气份额”,代入 Rudnick–Milton 式;量子率为示意。
import math

C0, CA = 420.0, 38000.0
N, I, T = 8, 1, 2.0


def f_rebreathed(c):
    return (c - C0) / CA


def p_inf(c, q):
    return 1.0 - math.exp(-f_rebreathed(c) * I * q * T / N)


if __name__ == "__main__":
    print("CO2 ppm  rebreathed  air in 1 L  P q=5   P q=20  P q=100")
    for c in (600, 800, 1000, 1400, 2000, 3000):
        f = f_rebreathed(c)
        print("{:7d} {:11.4f} {:8.1f} mL {:7.4f} {:7.4f} {:8.4f}".format(
            c, f, 1000 * f, p_inf(c, 5), p_inf(c, 20), p_inf(c, 100)))
    r = p_inf(1400, 20) / p_inf(800, 20)
    print("risk ratio 1400 vs 800 ppm at q = 20: {:.2f}".format(r))
    print("excess ratio (1400-420)/(800-420): {:.2f}".format(980 / 380))

Single source and citation

Fan, Y. (2026). Indoor CO2 and Cognitive Decline, Bernoulli Cross-Ventilation and an Engineering Re-reading of 'Storing Wind, Gathering Qi' (Version 1.0.0), Chapter 6: A Concentration Is Not a Dose: Confounding, Rebreathed Air and Sensor Error. 5D Library. DOI pending

DOI pending · monograph page goes live after publication · 5DL-B-194 · v1.0.0 · CC-BY-NC-ND-4.0

BibTeX
@book{fan2026194,
  author    = {Fan, Yafu},
  title     = {Indoor CO2 and Cognitive Decline, Bernoulli Cross-Ventilation and an Engineering Re-reading of 'Storing Wind, Gathering Qi'},
  year      = {2026},
  publisher = {5D Library},
  edition   = {1.0.0},
  note      = {DOI pending}
}

Other chapter answers in this book