What does Indoor CO2 and the Cross Draught conclude, in numbers, about “A Concentration Is Not a Dose: Confounding, Rebreathed Air and Sensor Error”?
Answer: Chapter 6 shows that field data cannot separate carbon dioxide from bioeffluents, and reads 1400 ppm as a rebreathed fraction of 0.0258.
Scope of the numbers: Marked boxes separate published evidence, runnable Python calculations (21 programs), classical sources and the author's hypotheses.
Data table
The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 0.0258, 1400
| CO2 ppm | rebreathed | air in 1 L | P q=5 | P q=20 | P q=100 |
| 600 | 0.0047 | 4.7 mL | 0.0059 | 0.0234 | 0.1117 |
| 800 | 0.0100 | 10.0 mL | 0.0124 | 0.0488 | 0.2212 |
| 1000 | 0.0153 | 15.3 mL | 0.0189 | 0.0735 | 0.3172 |
| 1400 | 0.0258 | 25.8 mL | 0.0317 | 0.1210 | 0.4752 |
| 2000 | 0.0416 | 41.6 mL | 0.0506 | 0.1877 | 0.6464 |
| 3000 | 0.0679 | 67.9 mL | 0.0814 | 0.2879 | 0.8168 |
| risk ratio 1400 vs 800 ppm at q = 20: 2.48 | |||||
| excess ratio (1400-420)/(800-420): 2.58 |
Show the full program
# Chapter 6. p62: CO2 as a meter of rebreathed air (Rudnick and Milton).
# Model: rebreathed fraction f = (C - C0) / Ca with exhaled-breath CO2
# Ca = 38000 ppm; the steady-state Wells-Riley form of Rudnick and Milton
# 2003 gives the chance that one susceptible person is infected,
# P = 1 - exp(-f I q t / n),
# with I infectors, q quanta per hour, t hours, n people. One infector,
# n = 8, t = 2 h; the quanta rates are illustrative, not disease data.
# 以 CO2 读出“再呼吸空气份额”,代入 Rudnick–Milton 式;量子率为示意。
import math
C0, CA = 420.0, 38000.0
N, I, T = 8, 1, 2.0
def f_rebreathed(c):
return (c - C0) / CA
def p_inf(c, q):
return 1.0 - math.exp(-f_rebreathed(c) * I * q * T / N)
if __name__ == "__main__":
print("CO2 ppm rebreathed air in 1 L P q=5 P q=20 P q=100")
for c in (600, 800, 1000, 1400, 2000, 3000):
f = f_rebreathed(c)
print("{:7d} {:11.4f} {:8.1f} mL {:7.4f} {:7.4f} {:8.4f}".format(
c, f, 1000 * f, p_inf(c, 5), p_inf(c, 20), p_inf(c, 100)))
r = p_inf(1400, 20) / p_inf(800, 20)
print("risk ratio 1400 vs 800 ppm at q = 20: {:.2f}".format(r))
print("excess ratio (1400-420)/(800-420): {:.2f}".format(980 / 380))Single source and citation
Fan, Y. (2026). Indoor CO2 and Cognitive Decline, Bernoulli Cross-Ventilation and an Engineering Re-reading of 'Storing Wind, Gathering Qi' (Version 1.0.0), Chapter 6: A Concentration Is Not a Dose: Confounding, Rebreathed Air and Sensor Error. 5D Library. DOI pending
DOI pending · monograph page goes live after publication · 5DL-B-194 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026194,
author = {Fan, Yafu},
title = {Indoor CO2 and Cognitive Decline, Bernoulli Cross-Ventilation and an Engineering Re-reading of 'Storing Wind, Gathering Qi'},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
note = {DOI pending}
}Other chapter answers in this book
- Chapter 1 · 1400 ppm in the Meeting Room: Three Controlled Exposure Experiments and Decision Scores
- Chapter 2 · The Stirred Tank: How an Eight-Person Meeting Room Climbs to 1400 ppm
- Chapter 3 · The Clean Air Delivery Rate of a Pot Plant: the Arithmetic of a Hundred Pots per Square Metre
- Chapter 4 · Bernoulli's Orifice and the Cross Draught: Wind Pressure, Stack Pressure and Openings in Series
- Chapter 5 · Pulse Ventilation and Dynamic Programming: a Window Schedule inside a Sawtooth
- Chapter 7 · Classical Sources East and West: Storing Wind and Gathering Qi in the Zangshu, and the Eight Winds of Vitruvius
- Chapter 8 · The Empirical Loop: Studio Ventilation Schedules, Reception-Room Closing Rates and a Plan for Refutation