关于「会议室里的 1400 ppm:三项受控暴露实验与决策测验分数」,《室内二氧化碳与穿堂风》给出的定量结论是什么?

结论:第一章重算艾伦等人的表格,复核 0.503 的降幅,并说明若给零效应一半权重,1400 ppm 处的预计下降从 0.446 缩到 0.223。

数据口径:书中的房间、人数、呼出量与风压系数均为示意参数;全部计算由书中程序生成;本书不是医疗建议,不对任何健康结果作出承诺,对经营者的建议为非个人化的经营建议。 书中以标注框区分已发表的证据、可运行的 Python 计算(21 段程序)、原典与作者的假说。

English version

对照数据表

下表数字由本章 Python 程序原样打印,可重新运行复现。 程序只用 Python 标准库与结论吻合的打印值: 0.223, 0.446, 1400

predicted fall of the average score, relative to 550 ppm
reading700 945 1000 1400 2500
A Allen reported0.079 0.207 0.236 0.446 1.000
B p11 refit0.084 0.221 0.252 0.476 1.000
C Zhang null0.000 0.000 0.000 0.000 0.000
weight on null fall at 1400 (A) fall at 1400 (B)
0.000.446 0.476
0.250.335 0.357
0.500.223 0.238
0.750.112 0.119
0.900.045 0.048
Satish 2012, 2500 ppm7 scales, raw ratios 0.06 to 0.56
null weight that brings A below a 0.10 fall0.776
查看完整验算程序
# Chapter 1. p12: three dose-response readings of pure CO2 at 1400 ppm.
# Readings: (A) Allen 2016 reported slope, 21 % of the average score per
# 400 ppm; (B) the linear fit of p11, 0.224 per 400 ppm; (C) the null of
# Zhang et al. 2017, no effect of pure CO2 up to 3000 ppm. A weight w on
# the null gives a mixture; the sweep shows how fast the headline shrinks.
# The mixture weights are illustrative, not a meta-analysis.
# 三种剂量反应读法与零效应权重的敏感度扫描;权重为示意。
import math

BASE = 550.0      # ppm, the Green+ level of Allen 2016
TARGET = 1400.0   # ppm, the high CO2 day
SLOPES = (("A Allen reported", 0.21), ("B p11 refit", 0.224))


def drop(slope_per_400, c):
    return min(1.0, slope_per_400 * (c - BASE) / 400.0)


if __name__ == "__main__":
    print("predicted fall of the average score, relative to 550 ppm")
    print("reading            700    945   1000   1400   2500")
    for name, k in SLOPES:
        row = "".join("{:7.3f}".format(drop(k, c))
                      for c in (700, 945, 1000, 1400, 2500))
        print("{:16s}{}".format(name, row))
    print("{:16s}{}".format("C Zhang null", "{:7.3f}".format(0.0) * 5))
    print("weight on null   fall at 1400 (A)   fall at 1400 (B)")
    for w in (0.0, 0.25, 0.5, 0.75, 0.9):
        fa = math.fsum([(1 - w) * drop(0.21, TARGET), w * 0.0])
        fb = math.fsum([(1 - w) * drop(0.224, TARGET), w * 0.0])
        print("{:12.2f}{:17.3f}{:19.3f}".format(w, fa, fb))
    print("Satish 2012, 2500 ppm: 7 scales, raw ratios 0.06 to 0.56")
    w10 = 1 - 0.10 / drop(0.21, TARGET)
    print("null weight that brings A below a 0.10 fall: {:.3f}".format(w10))

唯一数据源与引用

范雅福(Fan, Y.). (2026). 《室内二氧化碳认知衰减、穿堂风伯努利换气与藏风聚气的通风工程重读母典》第 1 章「会议室里的 1400 ppm:三项受控暴露实验与决策测验分数」(版本 1.0.0). 5D Library. DOI 待发布

DOI 待发布 · 专著页正式发布后上线(本站暂无专著页) · 5DL-B-194 · v1.0.0 · CC-BY-NC-ND-4.0

BibTeX
@book{fan2026194,
  author    = {Fan, Yafu},
  title     = {Indoor CO2 and Cognitive Decline, Bernoulli Cross-Ventilation and an Engineering Re-reading of 'Storing Wind, Gathering Qi'},
  year      = {2026},
  publisher = {5D Library},
  edition   = {1.0.0},
  note      = {DOI pending}
}

本书其他章节结论