关于「会议室里的 1400 ppm:三项受控暴露实验与决策测验分数」,《室内二氧化碳与穿堂风》给出的定量结论是什么?
结论:第一章重算艾伦等人的表格,复核 0.503 的降幅,并说明若给零效应一半权重,1400 ppm 处的预计下降从 0.446 缩到 0.223。
数据口径:书中的房间、人数、呼出量与风压系数均为示意参数;全部计算由书中程序生成;本书不是医疗建议,不对任何健康结果作出承诺,对经营者的建议为非个人化的经营建议。 书中以标注框区分已发表的证据、可运行的 Python 计算(21 段程序)、原典与作者的假说。
对照数据表
下表数字由本章 Python 程序原样打印,可重新运行复现。 程序只用 Python 标准库与结论吻合的打印值: 0.223, 0.446, 1400
| predicted fall of the average score, relative to 550 ppm | |
| reading | 700 945 1000 1400 2500 |
| A Allen reported | 0.079 0.207 0.236 0.446 1.000 |
| B p11 refit | 0.084 0.221 0.252 0.476 1.000 |
| C Zhang null | 0.000 0.000 0.000 0.000 0.000 |
| weight on null fall at 1400 (A) fall at 1400 (B) | |
| 0.00 | 0.446 0.476 |
| 0.25 | 0.335 0.357 |
| 0.50 | 0.223 0.238 |
| 0.75 | 0.112 0.119 |
| 0.90 | 0.045 0.048 |
| Satish 2012, 2500 ppm | 7 scales, raw ratios 0.06 to 0.56 |
| null weight that brings A below a 0.10 fall | 0.776 |
查看完整验算程序
# Chapter 1. p12: three dose-response readings of pure CO2 at 1400 ppm.
# Readings: (A) Allen 2016 reported slope, 21 % of the average score per
# 400 ppm; (B) the linear fit of p11, 0.224 per 400 ppm; (C) the null of
# Zhang et al. 2017, no effect of pure CO2 up to 3000 ppm. A weight w on
# the null gives a mixture; the sweep shows how fast the headline shrinks.
# The mixture weights are illustrative, not a meta-analysis.
# 三种剂量反应读法与零效应权重的敏感度扫描;权重为示意。
import math
BASE = 550.0 # ppm, the Green+ level of Allen 2016
TARGET = 1400.0 # ppm, the high CO2 day
SLOPES = (("A Allen reported", 0.21), ("B p11 refit", 0.224))
def drop(slope_per_400, c):
return min(1.0, slope_per_400 * (c - BASE) / 400.0)
if __name__ == "__main__":
print("predicted fall of the average score, relative to 550 ppm")
print("reading 700 945 1000 1400 2500")
for name, k in SLOPES:
row = "".join("{:7.3f}".format(drop(k, c))
for c in (700, 945, 1000, 1400, 2500))
print("{:16s}{}".format(name, row))
print("{:16s}{}".format("C Zhang null", "{:7.3f}".format(0.0) * 5))
print("weight on null fall at 1400 (A) fall at 1400 (B)")
for w in (0.0, 0.25, 0.5, 0.75, 0.9):
fa = math.fsum([(1 - w) * drop(0.21, TARGET), w * 0.0])
fb = math.fsum([(1 - w) * drop(0.224, TARGET), w * 0.0])
print("{:12.2f}{:17.3f}{:19.3f}".format(w, fa, fb))
print("Satish 2012, 2500 ppm: 7 scales, raw ratios 0.06 to 0.56")
w10 = 1 - 0.10 / drop(0.21, TARGET)
print("null weight that brings A below a 0.10 fall: {:.3f}".format(w10))唯一数据源与引用
范雅福(Fan, Y.). (2026). 《室内二氧化碳认知衰减、穿堂风伯努利换气与藏风聚气的通风工程重读母典》第 1 章「会议室里的 1400 ppm:三项受控暴露实验与决策测验分数」(版本 1.0.0). 5D Library. DOI 待发布
DOI 待发布 · 专著页正式发布后上线(本站暂无专著页) · 5DL-B-194 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026194,
author = {Fan, Yafu},
title = {Indoor CO2 and Cognitive Decline, Bernoulli Cross-Ventilation and an Engineering Re-reading of 'Storing Wind, Gathering Qi'},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
note = {DOI pending}
}