关于「实证闭环:工作室换气排程、会客室成交率与证伪方案」,《室内二氧化碳与穿堂风》给出的定量结论是什么?
结论:第八章给出工作室、直播间与会客室的实证闭环、蒸馏小工具“换气排程器”(示范直播间开窗时间占 0.243)和 32 人的预注册配对检验,中等效应下把握度为 0.801;成交率检验需要 2754 场会谈,故只作监测。书中以标注框区分已发表的证据、可运行的 Python 计算(21 段程序)、原典与作者的假说。
数据口径:书中的房间、人数、呼出量与风压系数均为示意参数;全部计算由书中程序生成;本书不是医疗建议,不对任何健康结果作出承诺,对经营者的建议为非个人化的经营建议。 书中以标注框区分已发表的证据、可运行的 Python 计算(21 段程序)、原典与作者的假说。
对照数据表
下表数字由本章 Python 程序原样打印,可重新运行复现。 程序只用 Python 标准库与结论吻合的打印值: 0.801, 32
| test 1, n | 32 paired share significant sig. lower |
| no CO2 effect | 0.058 0.034 |
| small, dz 0.3 | 0.427 0.001 |
| medium, dz 0.5 | 0.801 0.000 |
| Allen-like, dz 1.0 | 1.000 0.000 |
| test 2, 120 meetings/arm share significant | |
| no lift | 0.054 |
| lift 0.05 | 0.123 |
| lift 0.176 | 0.802 |
查看完整验算程序
# Chapter 8. p83: how often the pre-registered tests reach each verdict.
# Test 1: 32 people, each does the same decision task once at about
# 600 ppm and once at 1400 ppm (pure CO2 dosed, order balanced); verdict
# by a two-sided paired test on the mean difference (normal approx).
# Test 2: 120 client meetings per arm, closing rate 0.30 at baseline;
# two-proportion z test. 4000 simulated studies per row, fixed seed.
# True effects are scenarios, not claims.
# 预注册检验的蒙特卡洛:各情景下“支持 / 推翻”的频率;固定种子。
import math
import random
rng = random.Random(20261112)
REPS = 4000
def paired_reject(n, dz):
d = [rng.gauss(dz, 1.0) for _ in range(n)]
m = math.fsum(d) / n
sd = math.sqrt(math.fsum((x - m) ** 2 for x in d) / (n - 1))
return abs(m / (sd / math.sqrt(n))) > 1.96, m < 0
def prop_reject(n, p1, p2):
a = len([1 for _ in range(n) if rng.random() < p1])
b = len([1 for _ in range(n) if rng.random() < p2])
pb = (a + b) / (2.0 * n)
se = math.sqrt(2 * pb * (1 - pb) / n)
return se > 0 and abs(b - a) / n / se > 1.96
if __name__ == "__main__":
print("test 1, n = 32 paired share significant sig. lower")
for label, dz in (("no CO2 effect", 0.0), ("small, dz 0.3", 0.3),
("medium, dz 0.5", 0.5), ("Allen-like, dz 1.0", 1.0)):
sig = neg = 0
for _ in range(REPS):
s, wrong = paired_reject(32, dz)
sig += s
neg += s and wrong
print("{:22s} {:19.3f} {:11.3f}".format(label, sig / REPS,
neg / REPS))
print("test 2, 120 meetings/arm share significant")
for label, lift in (("no lift", 0.0), ("lift 0.05", 0.05),
("lift 0.176", 0.176)):
hits = 0
for _ in range(REPS):
hits += prop_reject(120, 0.30, 0.30 + lift)
print("{:22s} {:19.3f}".format(label, hits / REPS))唯一数据源与引用
范雅福(Fan, Y.). (2026). 《室内二氧化碳认知衰减、穿堂风伯努利换气与藏风聚气的通风工程重读母典》第 8 章「实证闭环:工作室换气排程、会客室成交率与证伪方案」(版本 1.0.0). 5D Library. DOI 待发布
DOI 待发布 · 专著页正式发布后上线(本站暂无专著页) · 5DL-B-194 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026194,
author = {Fan, Yafu},
title = {Indoor CO2 and Cognitive Decline, Bernoulli Cross-Ventilation and an Engineering Re-reading of 'Storing Wind, Gathering Qi'},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
note = {DOI pending}
}