关于「穿堂风的伯努利孔口:风压、热压与开口串联」,《室内二氧化碳与穿堂风》给出的定量结论是什么?

结论:第四章用伯努利孔口流公式说明,驱动每小时 694 立方米穿堂风的压差只有 1.92 帕。

数据口径:书中的房间、人数、呼出量与风压系数均为示意参数;全部计算由书中程序生成;本书不是医疗建议,不对任何健康结果作出承诺,对经营者的建议为非个人化的经营建议。 书中以标注框区分已发表的证据、可运行的 Python 计算(21 段程序)、原典与作者的假说。

English version

对照数据表

下表数字由本章 Python 程序原样打印,可重新运行复现。 程序只用 Python 标准库与结论吻合的打印值: 1.92, 694

equal openings A1 = A2; Q in m^3/h and air changes per hour
A each m2 U1 m/s U=2 m/s U=3 m/s U=5 m/s
0.10139 1.7 278 3.3 417 5.0 694 8.3
0.25347 4.1 694 8.3 1042 12.4 1736 20.7
0.50694 8.3 1389 16.5 2083 24.8 3472 41.3
1.001389 16.5 2778 33.1 4167 49.6 6944 82.7
dP at 2 m/s across the building1.92 Pa
A1 1.0 m2 with A2 0.25 m2 at 2 m/s953 m^3/h
gain over 0.25 + 0.25 m21.372 times
查看完整验算程序
# Chapter 4. p41: wind-driven cross ventilation through two openings.
# Model: Bernoulli orifice flow Q = Cd A sqrt(2 dP / rho). Wind gives
# dP = 0.5 rho U^2 dCp across the building, so for two openings in series
# Q = Cd A_eff U sqrt(dCp), with 1/A_eff^2 = 1/A1^2 + 1/A2^2.
# Cd 0.61 (sharp-edged orifice), dCp 0.8 (windward +0.5, leeward -0.3)
# and the room of p21 (84 m^3) are illustrative textbook values.
# 风压驱动的穿堂风:两个开口串联的伯努利孔口流;系数为示意教科书值。
import math

RHO = 1.2
CD = 0.61
DCP = 0.8
V = 84.0


def a_eff(a1, a2):
    return 1.0 / math.sqrt(1.0 / a1 ** 2 + 1.0 / a2 ** 2)


def q_wind(a1, a2, u, dcp=DCP, cd=CD):
    dp = 0.5 * RHO * u * u * dcp
    return cd * a_eff(a1, a2) * math.sqrt(2.0 * dp / RHO)


if __name__ == "__main__":
    print("equal openings A1 = A2; Q in m^3/h and air changes per hour")
    print("A each m2   U=1 m/s       U=2 m/s       U=3 m/s       U=5 m/s")
    for a in (0.1, 0.25, 0.5, 1.0):
        cells = []
        for u in (1.0, 2.0, 3.0, 5.0):
            q = q_wind(a, a, u) * 3600
            cells.append("{:6.0f} {:5.1f}".format(q, q / V))
        print("{:8.2f}  ".format(a) + "  ".join(cells))
    print("dP at 2 m/s across the building: {:.2f} Pa".format(
        0.5 * RHO * 4 * DCP))
    big = q_wind(1.0, 0.25, 2.0) * 3600
    small = q_wind(0.25, 0.25, 2.0) * 3600
    print("A1 1.0 m2 with A2 0.25 m2 at 2 m/s: {:.0f} m^3/h".format(big))
    print("gain over 0.25 + 0.25 m2: {:.3f} times".format(big / small))

唯一数据源与引用

范雅福(Fan, Y.). (2026). 《室内二氧化碳认知衰减、穿堂风伯努利换气与藏风聚气的通风工程重读母典》第 4 章「穿堂风的伯努利孔口:风压、热压与开口串联」(版本 1.0.0). 5D Library. DOI 待发布

DOI 待发布 · 专著页正式发布后上线(本站暂无专著页) · 5DL-B-194 · v1.0.0 · CC-BY-NC-ND-4.0

BibTeX
@book{fan2026194,
  author    = {Fan, Yafu},
  title     = {Indoor CO2 and Cognitive Decline, Bernoulli Cross-Ventilation and an Engineering Re-reading of 'Storing Wind, Gathering Qi'},
  year      = {2026},
  publisher = {5D Library},
  edition   = {1.0.0},
  note      = {DOI pending}
}

本书其他章节结论