What does Biphasic Light Dose and Thermal Limits conclude, in numbers, about “Optical Attenuation in Tissue: the Beer–Lambert Law and the Diffusion Approximation”?

Answer: Chapter 3 computes tissue attenuation with the diffusion approximation; with an illustrative window ratio of 49.5, a surface kept below the upper edge serves depths only to 18.26 mm at 810 nm.

Scope of the numbers: It writes only physical quantities (irradiance, fluence, temperature rise, duty cycle) and dose ranges reported in published studies; all devices and parameters are illustrative and all calculations are generated by its programs. It is not medical advice and claims no effect of any kind; anyone planning a self-experiment must first consult a licensed physician.

中文版

Data table

The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 18.26, 49.5, 810

window ratio HI/LO49.5; ln(HI/LO) = 3.901
band delta mm k z_peak mm z_max mm
630 nm2.69 1 5.25 10.50
630 nm2.69 3 8.20 13.45
810 nm4.68 1 9.13 18.26
810 nm4.68 3 14.27 23.40
980 nm3.15 1 6.15 12.29
980 nm3.15 3 9.61 15.75
810 nm, k1: surface fluence needed for the peak at depth z
z2 mm F0 0.823 J/cm^2 F0 / HI 0.22
z5 mm F0 1.563 J/cm^2 F0 / HI 0.41
z9 mm F0 3.674 J/cm^2 F0 / HI 0.97
z15 mm F0 13.242 J/cm^2 F0 / HI 3.50
depth gained by widening the window, 810 nm, k1:
HI/LO36.6 z_max 16.8 mm
HI/LO53.9 z_max 18.7 mm
HI/LO107.9 z_max 21.9 mm
HI/LO1269.2 z_max 33.4 mm
Show the full program
# Chapter 3. p32: one surface fluence cannot keep every depth inside a
# dose window.
# Window: the half-maximum band of the illustrative fit of p12, LO
# 0.0764 to HI 3.78 J/cm^2, peak 0.537 J/cm^2. Diffuse fluence at depth
# z is k * F0 * exp(-z / delta) (p31); k is a sub-surface build-up
# factor from back-scatter, set to 1 (none) or 3 (illustrative).
# If the surface layer must stay at or below HI, the deepest layer that
# can still receive LO lies at z_max = delta * ln(k * HI / LO), and the
# deepest layer that can receive the peak at z_pk = delta*ln(k*HI/D*).
# A wider window (larger HI / LO) buys depth only logarithmically.
import math

LO, HI, DSTAR = 0.0764, 3.78, 0.537
DELTA = [("630 nm", 2.69), ("810 nm", 4.68), ("980 nm", 3.15)]

print("window ratio HI/LO = %.1f; ln(HI/LO) = %.3f"
      % (HI / LO, math.log(HI / LO)))
print("band     delta mm   k   z_peak mm   z_max mm")
for name, d in DELTA:
    for k in (1.0, 3.0):
        print("%-7s  %8.2f  %2.0f  %9.2f  %9.2f"
              % (name, d, k, d * math.log(k * HI / DSTAR),
                 d * math.log(k * HI / LO)))
print("810 nm, k = 1: surface fluence needed for the peak at depth z")
for z in (2.0, 5.0, 9.0, 15.0):
    f0 = DSTAR * math.exp(z / 4.68)
    print("  z %4.0f mm   F0 %8.3f J/cm^2   F0 / HI %7.2f"
          % (z, f0, f0 / HI))
print("depth gained by widening the window, 810 nm, k = 1:")
for ratio in (36.6, 53.9, 107.9, 1269.2):
    print("  HI/LO %7.1f   z_max %5.1f mm" % (ratio, 4.68 * math.log(ratio)))

Single source and citation

Fan, Y. (2026). The Biphasic Dose Window of Photobiomodulation: Arrhenius Thermal Limits and Exposure Times under Pulsed Modulation (Version 1.0.0), Chapter 3: Optical Attenuation in Tissue: the Beer–Lambert Law and the Diffusion Approximation. 5D Library. DOI pending

DOI pending · monograph page goes live after publication · 5DL-B-287 · v1.0.0 · CC-BY-NC-ND-4.0

BibTeX
@book{fan2026287,
  author    = {Fan, Yafu},
  title     = {The Biphasic Dose Window of Photobiomodulation: Arrhenius Thermal Limits and Exposure Times under Pulsed Modulation},
  year      = {2026},
  publisher = {5D Library},
  edition   = {1.0.0},
  note      = {DOI pending}
}

Other chapter answers in this book