关于「停留上限:三条限值、一张表与四万次抽样」,《玻璃电极放电与臭氧暴露》给出的定量结论是什么?

结论:第六章把三条公开限值合成停留上限表,源强上限为每小时 4.04 毫克,四万次抽样中有 0.0454 超过器械上限。

数据口径:书中参数为示意;全部计算由书中程序生成;本书不是医疗建议,不宣称任何健康或美容功效。 第六章把三条公开限值合成停留上限表,源强上限为每小时 4.04 毫克,四万次抽样中有 0.0454 超过器械上限。

English version

对照数据表

下表数字由本章 Python 程序原样打印,可重新运行复现。 程序只用 Python 标准库与结论吻合的打印值: 4.04

ceiling 98.2, WHO 100, OSHA 196.3 ug/m^3
Y g/kWhP WACHC_N ug/m3ceilingWHO minOSHA min
50.050.524.8ok480480
50.056.023.4ok480480
50.200.539.3ok480480
50.206.033.5ok480480
50.500.568.4ok480480
50.506.053.8ok480480
51.000.5116.7over397480
51.006.087.6ok480480
200.050.539.3ok480480
200.056.033.5ok480480
200.200.597.4ok480480
200.206.074.1ok480480
200.500.5213.5over198437
200.506.0155.3over284480
201.000.5407.0over99219
201.006.0290.6over142313
largest source under the ceiling at ACH 0.5: 4.04 mg/h
NO2 1-hour guideline 200 ug/m^3 binds first only if NO2/O3 > 2.56
查看完整验算程序
# Chapter 6. p61: a stay limit per day from three published levels.
#  (a) 0.05 ppm, the ozone ceiling for indoor medical devices in the
#      US rule 21 CFR 801.415, used here as a ceiling on the near field;
#  (b) WHO 8-hour mean guideline, 100 ug/m^3;
#  (c) US OSHA limit, 0.1 ppm as an 8-hour TWA.
# Near-field ozone from the steady two-zone model of p42 (room 30 m^3,
# k_d 3 /h, s 0.05 m/s); indoor background 20 ug/m^3 (illustrative).
# Stay limit t = 480 min * (L - C_bg) / (C_N - C_bg), capped at 480.
# The whole source is assumed to reach the air (skin uptake ignored).
import math

PPB = 48.00 / 24.45
CEIL, WHO, OSHA = 50.0 * PPB, 100.0, 100.0 * PPB
VOL, KD, S, CBG = 30.0, 3.0, 0.05, 20.0
BETA = 0.5 * 4.0 * math.pi * 0.3 ** 2 * S * 3600.0


def near(g, lam):
    return CBG + g / ((lam + KD) * VOL) + g / BETA


def stay(c, lim):
    if c <= lim:
        return 480.0
    return max(0.0, 480.0 * (lim - CBG) / (c - CBG))


print("ceiling {:.1f}, WHO {:.0f}, OSHA {:.1f} ug/m^3".format(
    CEIL, WHO, OSHA))
print(" Y g/kWh  P W   ACH  C_N ug/m3  ceiling  WHO min  OSHA min")
for y in (5.0, 20.0):
    for p in (0.05, 0.2, 0.5, 1.0):
        for lam in (0.5, 6.0):
            g = y * p * 1000.0            # ug/h
            c = near(g, lam)
            ok = "ok" if c <= CEIL else "over"
            print("{:8.0f}  {:4.2f}  {:4.1f}  {:9.1f}  {:>7s}  {:7.0f}"
                  "  {:8.0f}".format(y, p, lam, c, ok, stay(c, WHO),
                                     stay(c, OSHA)))
g_max = (CEIL - CBG) / (1.0 / ((0.5 + KD) * VOL) + 1.0 / BETA)
print("largest source under the ceiling at ACH 0.5: {:.2f} mg/h".format(
    g_max / 1000.0))
print("NO2 1-hour guideline 200 ug/m^3 binds first only if NO2/O3 >"
      " {:.2f}".format(200.0 / (CEIL - CBG)))

唯一数据源与引用

范雅福(Fan, Y.). (2026). 《玻璃电极辉光放电电离层、微间隙臭氧菲克扩散与角质层脂质过氧化安全阈值》第 6 章「停留上限:三条限值、一张表与四万次抽样」(版本 1.0.0). 5D Library. DOI 待发布

DOI 待发布 · 专著页正式发布后上线(本站暂无专著页) · 5DL-B-168 · v1.0.0 · CC-BY-NC-ND-4.0

BibTeX
@book{fan2026168,
  author    = {Fan, Yafu},
  title     = {Glow-Discharge Ionisation in Glass Electrodes, Micro-Gap Ozone Diffusion and Safety Thresholds for Stratum-Corneum Lipid Peroxidation},
  year      = {2026},
  publisher = {5D Library},
  edition   = {1.0.0},
  note      = {DOI pending}
}

本书其他章节结论