What does Glass-Electrode Discharge and Ozone Exposure conclude, in numbers, about “Stay Limits: Three Published Levels, One Table and Forty Thousand Draws”?

Answer: Chapter 6 combines three published limits into a table of stay limits, with a source ceiling of 4.04 milligrams per hour, and finds 0.0454 of forty thousand draws above the device ceiling.

Scope of the numbers: Its parameters are illustrative; all calculations are generated by its programs; the book is not medical advice and claims no health or cosmetic benefit. Marked boxes separate published evidence, runnable Python calculations (21 programs), classical sources and the author's hypotheses.

中文版

Data table

The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 4.04

ceiling 98.2, WHO 100, OSHA 196.3 ug/m^3
Y g/kWhP WACHC_N ug/m3ceilingWHO minOSHA min
50.050.524.8ok480480
50.056.023.4ok480480
50.200.539.3ok480480
50.206.033.5ok480480
50.500.568.4ok480480
50.506.053.8ok480480
51.000.5116.7over397480
51.006.087.6ok480480
200.050.539.3ok480480
200.056.033.5ok480480
200.200.597.4ok480480
200.206.074.1ok480480
200.500.5213.5over198437
200.506.0155.3over284480
201.000.5407.0over99219
201.006.0290.6over142313
largest source under the ceiling at ACH 0.5: 4.04 mg/h
NO2 1-hour guideline 200 ug/m^3 binds first only if NO2/O3 > 2.56
Show the full program
# Chapter 6. p61: a stay limit per day from three published levels.
#  (a) 0.05 ppm, the ozone ceiling for indoor medical devices in the
#      US rule 21 CFR 801.415, used here as a ceiling on the near field;
#  (b) WHO 8-hour mean guideline, 100 ug/m^3;
#  (c) US OSHA limit, 0.1 ppm as an 8-hour TWA.
# Near-field ozone from the steady two-zone model of p42 (room 30 m^3,
# k_d 3 /h, s 0.05 m/s); indoor background 20 ug/m^3 (illustrative).
# Stay limit t = 480 min * (L - C_bg) / (C_N - C_bg), capped at 480.
# The whole source is assumed to reach the air (skin uptake ignored).
import math

PPB = 48.00 / 24.45
CEIL, WHO, OSHA = 50.0 * PPB, 100.0, 100.0 * PPB
VOL, KD, S, CBG = 30.0, 3.0, 0.05, 20.0
BETA = 0.5 * 4.0 * math.pi * 0.3 ** 2 * S * 3600.0


def near(g, lam):
    return CBG + g / ((lam + KD) * VOL) + g / BETA


def stay(c, lim):
    if c <= lim:
        return 480.0
    return max(0.0, 480.0 * (lim - CBG) / (c - CBG))


print("ceiling {:.1f}, WHO {:.0f}, OSHA {:.1f} ug/m^3".format(
    CEIL, WHO, OSHA))
print(" Y g/kWh  P W   ACH  C_N ug/m3  ceiling  WHO min  OSHA min")
for y in (5.0, 20.0):
    for p in (0.05, 0.2, 0.5, 1.0):
        for lam in (0.5, 6.0):
            g = y * p * 1000.0            # ug/h
            c = near(g, lam)
            ok = "ok" if c <= CEIL else "over"
            print("{:8.0f}  {:4.2f}  {:4.1f}  {:9.1f}  {:>7s}  {:7.0f}"
                  "  {:8.0f}".format(y, p, lam, c, ok, stay(c, WHO),
                                     stay(c, OSHA)))
g_max = (CEIL - CBG) / (1.0 / ((0.5 + KD) * VOL) + 1.0 / BETA)
print("largest source under the ceiling at ACH 0.5: {:.2f} mg/h".format(
    g_max / 1000.0))
print("NO2 1-hour guideline 200 ug/m^3 binds first only if NO2/O3 >"
      " {:.2f}".format(200.0 / (CEIL - CBG)))

Single source and citation

Fan, Y. (2026). Glow-Discharge Ionisation in Glass Electrodes, Micro-Gap Ozone Diffusion and Safety Thresholds for Stratum-Corneum Lipid Peroxidation (Version 1.0.0), Chapter 6: Stay Limits: Three Published Levels, One Table and Forty Thousand Draws. 5D Library. DOI pending

DOI pending · monograph page goes live after publication · 5DL-B-168 · v1.0.0 · CC-BY-NC-ND-4.0

BibTeX
@book{fan2026168,
  author    = {Fan, Yafu},
  title     = {Glow-Discharge Ionisation in Glass Electrodes, Micro-Gap Ozone Diffusion and Safety Thresholds for Stratum-Corneum Lipid Peroxidation},
  year      = {2026},
  publisher = {5D Library},
  edition   = {1.0.0},
  note      = {DOI pending}
}

Other chapter answers in this book