What does Acoustics and the Psychology of Built Space conclude, in numbers, about “Sabine and Eyring: Reverberation Time and Speech Clarity”?
Answer: Sabine's formula \(RT_{60} = 0.161V/A\) follows from an energy balance in a diffuse field, the constant 0.161 being \(24\ln 10/c\); Eyring's formula keeps \(1-\bar\alpha\) of the energy at each reflection, and the more absorption, the more the two differ (about 22 % shorter for Eyring at a mean coefficient of 0.4). In the illustrative calculation, one meeting room falls from about 2.1 s in glass and concrete to 0.80 s with an absorbent ceiling and 0.42 s with books and fabrics, its STI rising from 0.43 to 0.75 and its reverberant level falling by about 7 dB. "About 0.6 s" for speech rooms is a standard's upper limit rather than an experimental optimum; about 2 s for concert halls is design convention; "1.5–2.2 s for meditation spaces" has no basis. The next chapter turns to where reverberation theory breaks down: low frequencies in small rooms.
Scope of the numbers: This book is not medical advice; problems with hearing or sleep call for a doctor. Marked boxes separate published evidence, runnable Python calculations (15 programs, all checked), classical sources and the author's hypotheses.
Data table
The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 0.4, 0.42, 0.43, 0.6, 0.75, 1.5
| T (s) | C50 (dB) | STI at SNR +30 | +15 dB | +10 dB | | +5 dB | | 0 dB | |||||||
| 0.3 | | | +9.5 | | | 0.83 | | | 0.79 | | 0.71 | | 0.60 | | 0.46 |
| 0.4 | | | +6.6 | | | 0.78 | | | 0.74 | | 0.67 | | 0.57 | | 0.44 |
| 0.5 | | | +4.7 | | | 0.74 | | | 0.70 | | 0.64 | | 0.55 | | 0.42 |
| 0.6 | | | +3.3 | | | 0.70 | | | 0.67 | | 0.61 | | 0.53 | | 0.41 |
| 0.8 | | | +1.4 | | | 0.64 | | | 0.61 | | 0.57 | | 0.49 | | 0.38 |
| 1.0 | | | +0.0 | | | 0.59 | | | 0.57 | | 0.53 | | 0.46 | | 0.36 |
| 1.5 | | | -2.3 | | | 0.50 | | | 0.48 | | 0.46 | | 0.40 | | 0.31 |
| 2.0 | | | -3.9 | | | 0.44 | | | 0.43 | | 0.41 | | 0.36 | | 0.27 |
| 3.0 | | | -5.9 | | | 0.36 | | | 0.35 | | 0.33 | | 0.30 | | 0.22 |
| A glass + concrete | : STI 0.43 (poor) at SNR 15 dB, 0.36 at 5 dB; C50(1k) -3.7 dB | ||||||||
| B A + panel ceiling : STI 0.61 (good) at SNR 15 dB, 0.49 at 5 dB; C50(1k) +1.8 dB | |||||||||
| C wood, books, cloth: STI 0.75 (excellent) at SNR 15 dB, 0.57 at 5 dB; C50(1k) +7.4 dB |
Key formula
Show the full program
# Speech Transmission Index from the modulation transfer function of a diffuse room
# (exponential decay) plus steady noise:
# m(F) = 1 / sqrt(1 + (2 pi F T / 13.8)^2) / (1 + 10^(-SNR/10)).
# Octave weights alpha/beta as in IEC 60268-16 (2011+, male); no auditory masking or
# threshold corrections, no direct sound: a simplified textbook STI. Clarity C50 for an
# exponential decay.
import math
FM = [10 ** (k / 10) for k in range(-2, 12)] # 14 modulation freqs, 0.63-12.5
ALPHA = (0.085, 0.127, 0.230, 0.233, 0.309, 0.224, 0.173) # 125 Hz ... 8 kHz
BETA = (0.085, 0.078, 0.065, 0.011, 0.047, 0.095)
def mti(T, snr):
tis = []
for F in FM:
m = 1 / math.sqrt(1 + (2 * math.pi * F * T / 13.8) ** 2) / (1 + 10 ** (-snr / 10))
snr_app = max(-15.0, min(15.0, 10 * math.log10(m / (1 - m)))) if m < 1 else 15.0
tis.append((snr_app + 15) / 30)
return sum(tis) / len(tis)
def sti(Ts, snrs):
M = [mti(T, s) for T, s in zip(Ts, snrs)]
return (sum(a * m for a, m in zip(ALPHA, M))
- sum(b * math.sqrt(M[k] * M[k + 1]) for k, b in enumerate(BETA)))
def c50(T): # early (0-50 ms) / late energy, dB
return round(10 * math.log10(math.exp(13.8 * 0.05 / T) - 1), 1) + 0.0
LABEL = [(0.30, "bad"), (0.45, "poor"), (0.60, "fair"), (0.75, "good"),
(1.01, "excellent")]
word = lambda x: next(w for t, w in LABEL if x < t)
print(" T (s) | C50 (dB) | STI at SNR +30 | +15 dB | +10 dB | +5 dB | 0 dB")
for T in (0.3, 0.4, 0.5, 0.6, 0.8, 1.0, 1.5, 2.0, 3.0):
row = [sti([T] * 7, [s] * 7) for s in (30, 15, 10, 5, 0)]
print(f" {T:3.1f} | {c50(T):+5.1f} | {row[0]:.2f} | "
+ " | ".join(f"{x:.2f}" for x in row[1:]))
ROOMS = { # Sabine T per band of the three rooms of p01; 8 kHz taken equal to 4 kHz
"A glass + concrete": (2.47, 2.73, 2.24, 1.96, 1.85, 1.78, 1.78),
"B A + panel ceiling": (0.99, 0.83, 0.86, 0.75, 0.73, 0.89, 0.89),
"C wood, books, cloth": (0.78, 0.55, 0.48, 0.37, 0.31, 0.34, 0.34)}
for name, Ts in ROOMS.items():
s15 = sti(Ts, [15] * 7)
print(f"{name:20s}: STI {s15:.2f} ({word(s15)}) at SNR 15 dB,"
f" {sti(Ts, [5] * 7):.2f} at 5 dB; C50(1k) {c50(Ts[3]):+.1f} dB")Single source and citation
Fan, Y. (2026). Architectural Acoustics, Reverberation Time and the Environmental Psychology of Built Space (Version 1.0.0), Chapter 1: Sabine and Eyring: Reverberation Time and Speech Clarity. 5D Library. https://doi.org/10.5281/zenodo.23782090
DOI: 10.5281/zenodo.23782090 · Read the monograph · 5DL-B-031 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026031,
author = {Fan, Yafu},
title = {Architectural Acoustics, Reverberation Time and the Environmental Psychology of Built Space},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
doi = {10.5281/zenodo.23782090},
url = {https://doi.org/10.5281/zenodo.23782090}
}Other chapter answers in this book
- Chapter 2 · Standing Waves, Room Modes and Low-Frequency Noise
- Chapter 3 · Open-Plan Offices and the Irrelevant Speech Effect
- Chapter 4 · Trees outside the Window: Fractal Dimension and Biophilic Design
- Chapter 5 · Illuminance, Spectrum and Ceiling Height
- Chapter 6 · Carbon Dioxide, Ventilation and Decision-Making