Architectural Acoustics, Reverberation Time and the Environmental Psychology of Built Space: chapter answers
The same people doing the same work feel very different in a meeting room of glass and concrete and in a study lined with books with trees outside the window; the difference is often put down to the "energy" of a place. This book takes it apart into measurable physical quantities and checks the research on each: the derivation of Sabine's formula RT60 = 0.161 V/A (the constant being 24 ln 10 / c) and Eyring's correction, with one illustrative meeting room falling from about 2.1 s to 0.42 s of reverberation and its speech transmission index (STI) rising from 0.43 to 0.75, while "about 0.6 s" f…
DOI 10.5281/zenodo.23782090 · Read the monograph · 中文版
- Chapter 1 · Sabine and Eyring: Reverberation Time and Speech Clarity
Sabine's formula $RT_{60} = 0.161V/A$ follows from an energy balance in a diffuse field, the constant 0.161 being $24\ln 10/c$; Eyring's formula keeps $1-\bar\alpha$ of the energy at each reflection, and the more absorp… - Chapter 2 · Standing Waves, Room Modes and Low-Frequency Noise
The normal frequencies of a rectangular room are given by $f = \frac{c}{2}\sqrt{(n_x/L)^2 + (n_y/W)2 + (n_z/H)^2}$, and the number of modes grows as $f3$. At equal volume, a cube's 62 modes below 200 Hz fall on only 15… - Chapter 3 · Open-Plan Offices and the Irrelevant Speech Effect
The irrelevant speech effect is one of the most robust phenomena in cognitive psychology: background speech increases serial-recall errors by about half on average, almost regardless of level. But it does not require un… - Chapter 4 · Trees outside the Window: Fractal Dimension and Biophilic Design
Ulrich's 1984 comparison of records (23 pairs; 7.96 versus 8.70 days in hospital) opened research on window views, but it was not a randomised trial and has not been directly replicated; a systematic review gives attent… - Chapter 5 · Illuminance, Spectrum and Ceiling Height
The effect of light on ipRGCs should be measured as melanopic EDI at the eye rather than by colour temperature; the 2022 consensus recommends at least 250 lux during the day, no more than 10 lux from 3 hours before bed… - Chapter 6 · Carbon Dioxide, Ventilation and Decision-Making
Indoor CO~2~ is an indicator of ventilation, and 1,000 ppm is not a health limit. The well-mixed mass balance $V\,dC/dt = NG - Q(C - C_{out})$ shows that six people in a 48.6 m³ room at one air change per hour pass 1,00… - Chapter 8 · Practice and a Pre-Registered Trial
Chapter 8 gives a four-step checklist of environmental physics and a pre-registered within-participant randomised crossover trial comparing intelligible conversation (STI about 0.65) with the same conversation masked to…