What does Oscillations, Flattening and Recovery conclude, in numbers, about “The Variable That Moves in Days”?
Answer: Chapter 6 shows light fixed at seven in the morning making a three-hour delay worse, while light placed against the person's own temperature minimum closes it in eight to fourteen days; ten thousand lux for thirty minutes is worth 1.4713 times three hundred lux for thirty minutes but only 1.0299 times that three hundred lux left on for two hours.
Scope of the numbers: Its parameters are illustrative or synthetic; all figures are produced by the programs printed in the book; the book is not medical advice and does not diagnose. Marked boxes separate published evidence, runnable Python calculations (sixteen programs), classical sources and the author's hypotheses.
Data table
The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 1.0299, 1.4713
half the maximum effect is reached at 120 lux setting brightness duration fixed adaptive 10,000 lux, 30 min 0.9013 0.6000 -0.182 0.351 5,000 lux, 30 min 0.8659 0.6000 -0.175 0.338 1,000 lux, 30 min 0.7427 0.6000 -0.150 0.290 300 lux, 30 min 0.6126 0.6000 -0.124 0.239 300 lux, 120 min 0.6126 0.8571 -0.177 0.341 100 lux, 30 min 0.4772 0.6000 -0.096 0.186 a fixed hour of seven makes a 3.0 hour delay worse, because the minimum has moved to 8 and the light now falls before it rather than after it days to bring the delay under 0.5 hours, light placed 2.0 hours after the person's own minimum each day: 10,000 lux, 30 min 8 5,000 lux, 30 min 8 1,000 lux, 30 min 9 300 lux, 30 min 11 300 lux, 120 min 8 100 lux, 30 min 14 the very bright lamp is worth 1.4713 times the room light at the same thirty minutes, but only 1.0299 times the same room light left on for two hours so brightness buys less than the lamps claim and time buys more than people expect light at each clock hour, with the delay still 3.0 hours: clock hour shift 5 -0.4971 7 -0.1819
Show the full program
# Chapter 6. p11: Pulling the clock back with light. A phase that has
# drifted late is corrected by light in the morning, which advances the
# clock, and made worse by light in the evening, which delays it. The
# size of a day's shift is the product of three things: how bright the
# light is, how long it lasts, and where in the phase-response curve it
# falls. The brightness term saturates, with half the maximum effect
# near the level below, which is the fact the marketing of very bright
# lamps does not mention. The response curve is taken as a sine that
# crosses zero at the body's temperature minimum. The first result is
# not the one the protocol expects: a person whose clock is three hours
# late has a temperature minimum at eight in the morning, so light at
# seven falls before it and delays them further. Light has to be timed
# against the person's own minimum, not against the clock, and the hour
# has to move earlier as the phase comes back.
import math
AMAX, I_HALF, I_POW = 1.30, 120.0, 0.5 # hours a day at saturation
D_HALF = 20.0 # minutes for half the effect
TMIN = 5.0 # temperature minimum, hours
START_ERROR = 3.0 # hours late at the start
PI2 = 6.283185307179586
SETTINGS = (
("10,000 lux, 30 min", 10000.0, 30.0),
("5,000 lux, 30 min", 5000.0, 30.0),
("1,000 lux, 30 min", 1000.0, 30.0),
("300 lux, 30 min", 300.0, 30.0),
("300 lux, 120 min", 300.0, 120.0),
("100 lux, 30 min", 100.0, 30.0),
)
LIGHT_AT = 7.0 # the fixed clock hour the usual protocol names
OFFSET = 2.0 # hours after the person's own minimum, adaptive
def brightness(lux):
return lux ** I_POW / (I_HALF ** I_POW + lux ** I_POW)
def duration(minutes):
return minutes / (D_HALF + minutes)
def prc(hours_after_tmin):
# positive means an advance; light just after the minimum advances
return math.sin(PI2 * (hours_after_tmin % 24.0) / 24.0)
def shift_fixed(lux, minutes, error):
# light at a fixed clock hour, against a minimum that has moved late
return (AMAX * brightness(lux) * duration(minutes)
* prc(LIGHT_AT - (TMIN + error)))
def shift_adaptive(lux, minutes, error):
# light placed OFFSET hours after the person's own minimum each day
return AMAX * brightness(lux) * duration(minutes) * prc(OFFSET)
if __name__ == "__main__":
print(" half the maximum effect is reached at {:.0f} lux"
.format(I_HALF))
print(" setting brightness duration fixed adaptive")
for label, lux, mins in SETTINGS:
print(" {:<22}{:<13.4f}{:<11.4f}{:<7.3f}{:.3f}"
.format(label, brightness(lux), duration(mins),
shift_fixed(lux, mins, START_ERROR),
shift_adaptive(lux, mins, START_ERROR)))
print(" a fixed hour of seven makes a {:.1f} hour delay worse,"
.format(START_ERROR))
print(" because the minimum has moved to {:.0f} and the light now"
.format(TMIN + START_ERROR))
print(" falls before it rather than after it")
print(" days to bring the delay under 0.5 hours, light placed")
print(" {:.1f} hours after the person's own minimum each day:"
.format(OFFSET))
for label, lux, mins in SETTINGS:
err, days = START_ERROR, 0
while err > 0.5 and days < 200:
s = shift_adaptive(lux, mins, err)
if s <= 0.0:
break
err -= s
days += 1
print(" {:<22}{}".format(label, days if err <= 0.5
else "not within 200 days"))
a = brightness(10000.0) * duration(30.0)
b = brightness(300.0) * duration(30.0)
c = brightness(300.0) * duration(120.0)
print(" the very bright lamp is worth {:.4f} times the room light"
.format(a / b))
print(" at the same thirty minutes, but only {:.4f} times the same"
.format(a / c))
print(" room light left on for two hours")
print(" so brightness buys less than the lamps claim and time buys")
print(" more than people expect")
print(" light at each clock hour, with the delay still {:.1f} hours:"
.format(START_ERROR))
print(" clock hour shift")
for h in (5.0, 7.0, 9.0, 12.0, 17.0, 21.0, 23.0):
after = h - (TMIN + START_ERROR)
s = AMAX * brightness(10000.0) * duration(30.0) * prc(after)
print(" {:<13.0f}{:+.4f}".format(h, s))
best = max(((AMAX * brightness(10000.0) * duration(30.0)
* prc(h / 4.0 - (TMIN + START_ERROR)), h / 4.0)
for h in range(4 * 24)))
print(" the best clock hour for this person today is {:.2f}"
.format(best[1]))
print(" that is an artefact of the sine, which puts its maximum")
print(" {:.1f} hours after the minimum while measured curves peak"
.format(6.0))
print(" earlier, so the protocol above uses the conservative")
print(" offset of {:.1f} hours and not this one".format(OFFSET))
print(" evening light moves the clock the wrong way, so a bright")
print(" lamp used after work is worse than no lamp at all")Single source and citation
Fan, Y. (2026). HPA-Axis Coupled Oscillations, Cortisol Awakening Response Flattening and Burnout Recovery Kinetics (Version 1.0.0), Chapter 6: The Variable That Moves in Days. 5D Library. https://doi.org/10.5281/zenodo.24090252
DOI: 10.5281/zenodo.24090252 · Read the monograph · 5DL-B-097 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026097,
author = {Fan, Yafu},
title = {HPA-Axis Coupled Oscillations, Cortisol Awakening Response Flattening and Burnout Recovery Kinetics},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
doi = {10.5281/zenodo.24090252},
url = {https://doi.org/10.5281/zenodo.24090252}
}