What does Oscillations, Flattening and Recovery conclude, in numbers, about “The Receptor Counts Itself Down”?

Answer: Chapter 3 writes the receptor as a variable that counts itself down: at 2.5 times the normal mean, 0.7955 of the receptors are left, recovery has a time constant of 11.20 days, closing 0.90 of the gap takes 25.8 days and 0.95 takes 33.6, while two days of rest close only 0.1635.

Scope of the numbers: Its parameters are illustrative or synthetic; all figures are produced by the programs printed in the book; the book is not medical advice and does not diagnose. Marked boxes separate published evidence, runnable Python calculations (sixteen programs), classical sources and the author's hypotheses.

中文版

Data table

The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. printed values that match the answer: 0.1635, 0.7955, 0.90, 0.95, 11.20, 2.5

chronic load at 2.5 times normal leaves 0.7955 of the
receptors; recovery runs at a time constant of 11.20 days
day density share of the gap closed relative to normal
29.2837 0.1635 0.8289
79.9738 0.4647 0.8905
1410.5436 0.7135 0.9414
2110.8487 0.8466 0.9686
3011.0427 0.9313 0.9860
4511.1588 0.9820 0.9963
6011.1892 0.9953 0.9990
9011.1993 0.9997 0.9999
12011.1999 1.0000 1.0000
days to close 0.50 of the gap7.8
days to close 0.80 of the gap18.0
days to close 0.90 of the gap25.8
days to close 0.95 of the gap33.6
the time constant is the whole answer, and it is set by
receptor turnover, not by how tired anyone feels
turnover under load is faster, at 8.91 days, which is
why the fall is quicker than the recovery1.26 times
two days of rest close 0.1635 of the gap
and fourteen days close 0.7135
so the popular claim that a long weekend resets the axis
is wrong by more than an order of magnitude in time
Show the full program
# Chapter 3. p06: How long the receptor takes to come back. Once the
# load is removed and the hormone returns to its normal mean, receptor
# density climbs back towards its own steady state as a first-order
# process whose time constant is one over the total disposal rate. That
# time constant is the number this chapter exists to compute, because
# every popular claim about recovering from chronic stress is a claim
# about it. The starting density is the steady state under the chronic
# load; the target is the steady state at a normal mean.
SYNTH, BASAL, EXTRA = 1.0, 1.0 / 28.0, 3.0 / 28.0
KD, HILL = 1.0, 1.0
CHRONIC = 2.5                     # multiples of a normal mean
DAYS = (2, 7, 14, 21, 30, 45, 60, 90, 120)

def occupancy(c):
    return c ** HILL / (KD ** HILL + c ** HILL)

def steady(c):
    return SYNTH / (BASAL + EXTRA * occupancy(c))

def tau(c):
    return 1.0 / (BASAL + EXTRA * occupancy(c))

def density(t, start, target, tc):
    return target + (start - target) * 2.718281828459045 ** (-t / tc)

if __name__ == "__main__":
    start = steady(CHRONIC)
    target = steady(1.0)
    tc = tau(1.0)
    print("   chronic load at {:.1f} times normal leaves {:.4f} of the"
          .format(CHRONIC, start / target))
    print("   receptors; recovery runs at a time constant of {:.2f} days"
          .format(tc))
    print("   day    density   share of the gap closed   relative to normal")
    for d in DAYS:
        r = density(float(d), start, target, tc)
        print("   {:<7d}{:<10.4f}{:<26.4f}{:.4f}"
              .format(d, r, (r - start) / (target - start), r / target))
    for frac in (0.50, 0.80, 0.90, 0.95):
        lo, hi = 0.0, 1000.0
        for _ in range(60):
            mid = 0.5 * (lo + hi)
            r = density(mid, start, target, tc)
            if (r - start) / (target - start) < frac:
                lo = mid
            else:
                hi = mid
        print("   days to close {:.2f} of the gap: {:.1f}"
              .format(frac, 0.5 * (lo + hi)))
    print("   the time constant is the whole answer, and it is set by")
    print("   receptor turnover, not by how tired anyone feels")
    print("   turnover under load is faster, at {:.2f} days, which is"
          .format(tau(CHRONIC)))
    print("   why the fall is quicker than the recovery: {:.2f} times"
          .format(tc / tau(CHRONIC)))
    print("   two days of rest close {:.4f} of the gap"
          .format((density(2.0, start, target, tc) - start)
                  / (target - start)))
    print("   and fourteen days close {:.4f}"
          .format((density(14.0, start, target, tc) - start)
                  / (target - start)))
    print("   so the popular claim that a long weekend resets the axis")
    print("   is wrong by more than an order of magnitude in time")

Single source and citation

Fan, Y. (2026). HPA-Axis Coupled Oscillations, Cortisol Awakening Response Flattening and Burnout Recovery Kinetics (Version 1.0.0), Chapter 3: The Receptor Counts Itself Down. 5D Library. https://doi.org/10.5281/zenodo.24090252

DOI: 10.5281/zenodo.24090252 · Read the monograph · 5DL-B-097 · v1.0.0 · CC-BY-NC-ND-4.0

BibTeX
@book{fan2026097,
  author    = {Fan, Yafu},
  title     = {HPA-Axis Coupled Oscillations, Cortisol Awakening Response Flattening and Burnout Recovery Kinetics},
  year      = {2026},
  publisher = {5D Library},
  edition   = {1.0.0},
  doi       = {10.5281/zenodo.24090252},
  url       = {https://doi.org/10.5281/zenodo.24090252}
}

Other chapter answers in this book