HPA-Axis Coupled Oscillations, Cortisol Awakening Response Flattening and Burnout Recovery Kinetics: chapter answers
Why does chronic pressure first raise cortisol and later let it collapse? Why does catching up on sleep for two days fail to restore a receptor that has been downregulated? How bright does morning light have to be, and at what hour, to actually pull the clock back? This book writes these questions as runnable arithmetic and then asks when the answers hold. Its parameters are illustrative or synthetic; all figures are produced by the programs printed in the book; the book is not medical advice and does not diagnose. A low cortisol with a high corticotropin is both the end state of this book's…
DOI 10.5281/zenodo.24090252 · Read the monograph · 中文版
- Chapter 1 · A Loop with a Delay
Chapter 1 builds a delayed negative feedback loop out of the published half-lives of three hormones: above a delay of 9.8 minutes it oscillates, and at a fifteen-minute delay its period of 171.5 minutes is 2.29 times th… - Chapter 2 · What the Pulses Are For
Chapter 2 shows why the pulses exist: the same daily total in the sharpest pulses holds mean occupancy to 0.1132 of a flat infusion, while peak over mean rises from 1.000 to 16.667. - Chapter 3 · The Receptor Counts Itself Down
Chapter 3 writes the receptor as a variable that counts itself down: at 2.5 times the normal mean, 0.7955 of the receptors are left, recovery has a time constant of 11.20 days, closing 0.90 of the gap takes 25.8 days an… - Chapter 4 · Three Stages, and a Measure That Disagrees with Itself
Chapter 4 couples receptor downregulation to adrenal wear and gets three stages: cortisol above 1.30 on days 0 to 62, between them on days 63 to 178, and collapse below 0.80 from day 179, ending at 0.5680 with corticotr… - Chapter 5 · Five On, Two Off
Chapter 5 shows the five-on-two-off cycle settling at 0.8598 of rested and recovering only 0.3144 of the gap, while cutting the load by a third every day reaches only 0.8357. - Chapter 6 · The Variable That Moves in Days
Chapter 6 shows light fixed at seven in the morning making a three-hour delay worse, while light placed against the person's own temperature minimum closes it in eight to fourteen days; ten thousand lux for thirty minut… - Chapter 7 · Taking the Reckless as the Rule
Chapter 7 reads the Suwen's complaint about taking the reckless as the rule alongside Zhang Jingyue on the water and fire of the gate of life: a bedtime spread must stay within 21 minutes for 0.95 of days to fall inside… - Chapter 8 · The Month, and the Gate
Chapter 8 shows realistic adherence giving up 0.5014 of the gap and the safety gate stopping or referring 0.6315 of adults. Marked boxes separate published evidence, runnable Python calculations (sixteen programs), clas…
Illustrative model calculation, not a live quote