Water-Hardness Chemistry in Personal-Care Formulations, Calcium-Magnesium Chelation and Surfactant Foam-Deposition Enhancement: chapter answers
Three popular sentences circulate in the shampoo and shower categories: hard water makes a whole bottle stop working; adding more chelant to a formula softens hard water in the shower; and a deionised-water base marks a premium formula. This book refutes them one by one or draws the boundary inside which they hold. Calcium and magnesium first lower the critical micelle concentration and precipitate calcium salts only in an intermediate band of dilution during rinsing, so the loss is graded by surfactant system: soaps lose most, alkyl sulfates next, acyl glutamates sit in the middle, and ether…
DOI pending · monograph page goes live after publication · 5DL-B-389 · 中文版
- Chapter 1 · Four Units of Hardness and Six Illustrative Waters: the Effective Concentration of Calcium in Shower Water
Part B shows the six illustrative waters. W1 holds only 0.4 mmol/L, or 40.0 mg/L, and is soft. W2 is 100.1 mg/L and moderately hard. W3 is 160.1 mg/L and hard. W4, W5 and W6 come to 250.2, 350.3 and 500.4 mg/L, and all… - Chapter 2 · Critical Micelle Concentration, Solubility Products and the Loss Curves of Five Surfactant Classes
The first table reads as follows. Each cell is the total calcium concentration, in millimoles per litre, at which precipitation starts for the stated surfactant level. The fatty-acid soap stays below 0.001 in all four c… - Chapter 3 · From Lost Shares to Foam Height: Precipitated Particles and Foam Half-Life
The first table shows the thin state at 5 mmol/L, which corresponds to the first seconds of rinsing. In soft water all four classes give an initial height of 128.6 mm, because their surfactant concentration is the same.… - Chapter 4 · The Stoichiometry of Chelation and the Ceiling on Coverage: How Much Water Can a Formula's Chelant Soften?
A chelant binds calcium and magnesium one to one, mole for mole. With illustrative inputs, a single dose softens only 10.5 mL of W4 water and does not cover the 40 mL of lathering water; softening the water of one showe… - Chapter 5 · Conditional Stability Constants, the Contest between Calcium and Magnesium, and Dilution by Rinsing: Why a Chelant Neither Grips Hard nor Keeps Up
Chapter 5 computes conditional stability constants, which at pH 5.5 fall to 5.06 for EDTA and 2.90 for GLDA, and shows that during rinsing a chelant does not postpone precipitation by a single step. - Chapter 6 · The Deposition of Cationic Polymers: Charge Screening, Competition for Sites and the Coacervation Window
Chapter 6 covers the deposition of cationic polymers, where screening and bridging give coacervation-window width ratios of 0.677 and 1.323. - Chapter 7 · Classical Sources: Lu Yu on Waters, the Guanzi on Water, Hippocrates on Hard Water and Clark's Soap Test
The probability that a mountain water is softer than a river water is 0.8525, against an exact value of 0.8539, so the simulation and the analytic result agree. The probability that a river water is softer than a well w… - Chapter 8 · The Empirical Loop: a Weekly Water-Fit Ledger, Field Tools and Checker Specifications, and Pre-Registered Tests
Chapter 8 delivers a weekly water-fit ledger, the distilled Hard-Water Loss and Chelant Dosing Calculator, checker specifications for the four kits and pre-registered tests; a triangle test needs 42 assessors to detect…
Illustrative model calculation, not a live quote