What does Vocal Biomechanics and Auditory Feedback conclude, in numbers, about “Practice and a Pre-Registered Trial”?
Answer: Taking 0.4 dB as the smallest effect of interest (no minimal important difference in CPPS has been established for healthy speakers; this is an assumption for the author to confirm), a between-person standard deviation of 1.2 dB, a cautious baseline–outcome correlation of 0.7 and 90 % power, each arm needs 98 analysable participants, 196 in all; allowing about 10 % for unusable recordings or withdrawal, 109 are recruited per arm, 218 in all. If the correlation were only 0.6, 123 per arm would be needed. The standard deviation and correlation will be checked in a pilot used for this purpose only and not pooled into the main analysis.
Scope of the numbers: Marked boxes separate published evidence, runnable Python calculations (16 programs, all checked), classical sources and the author's hypotheses.
Data table
The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 0.4, 0.6, 0.7, 1.2, 10, 109
| sd 1.2 dB, alpha 0.05 two-sided, 90 % power; analysable participants per arm | |
| SESOI (dB) | rho | 0.6 | rho = 0.7 | rho = 0.8 |
| 0.3 | | 217 | 173 | 123 |
| 0.4 | | 123 | 98 | 70 |
| 0.5 | | 79 | 63 | 45 |
| chosen: SESOI 0.4 dB, rho 0.7 | 98 analysable per arm, 196 in all |
| allowing 10% loss (unusable recordings, withdrawal): recruit 109 per arm, 218 in all | |
| if rho were only 0.6 | 123 per arm would be needed |
Show the full program
# Sample size for the Chapter 8 trial: two parallel arms, 1:1, ANCOVA. Primary outcome:
# read-passage CPPS (dB) right after the session, adjusted for baseline (variance x
# 1-rho^2):
# n per arm = 2 (z_a + z_b)^2 sd^2 (1 - rho^2) / delta^2 + z_a^2 / 4 (normal approx.)
# Assumptions, to be checked in a pilot used for nothing else: between-person SD 1.2 dB,
# pre-post correlation 0.7 (cautious), smallest effect worth acting on 0.4 dB.
import math
from statistics import NormalDist
z = NormalDist().inv_cdf
def per_arm(delta, sd, rho, alpha=0.05, power=0.90):
za, zb = z(1 - alpha / 2), z(power)
n = 2 * (za + zb) ** 2 * sd ** 2 * (1 - rho ** 2) / delta ** 2 + za ** 2 / 4
return math.ceil(n)
SD, RHO, SESOI, LOSS = 1.2, 0.7, 0.4, 0.10
print(f"sd {SD} dB, alpha 0.05 two-sided, 90 % power; analysable participants per arm")
print(" SESOI (dB) | rho = 0.6 | rho = 0.7 | rho = 0.8")
for d in (0.3, 0.4, 0.5):
cells = " | ".join(f"{per_arm(d, SD, r):5d}" for r in (0.6, 0.7, 0.8))
print(f" {d:.1f} | {cells}")
n = per_arm(SESOI, SD, RHO)
rec = math.ceil(n / (1 - LOSS))
print(f"chosen: SESOI {SESOI} dB, rho {RHO} -> {n} analysable per arm, {2 * n} in all")
print(f"allowing {LOSS:.0%} loss (unusable recordings, withdrawal): "
f"recruit {rec} per arm, {2 * rec} in all")
print(f"if rho were only 0.6: {per_arm(SESOI, SD, 0.6)} per arm would be needed")Single source and citation
Fan, Y. (2026). Vocal Biomechanics, Non-Linear Source-Filter Coupling and Auditory-Motor Feedback (Version 1.0.0), Chapter 8: Practice and a Pre-Registered Trial. 5D Library. https://doi.org/10.5281/zenodo.23770084
DOI: 10.5281/zenodo.23770084 · Read the monograph · 5DL-B-029 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026029,
author = {Fan, Yafu},
title = {Vocal Biomechanics, Non-Linear Source-Filter Coupling and Auditory-Motor Feedback},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
doi = {10.5281/zenodo.23770084},
url = {https://doi.org/10.5281/zenodo.23770084}
}Other chapter answers in this book
- Chapter 1 · Why the Vocal Folds Vibrate by Themselves: Phase Difference and Threshold Pressure
- Chapter 2 · Nonlinear Source–Filter Coupling: Inertance, Compliance and the Semi-Occluded Tract
- Chapter 3 · The Singer's Formant and Orchestral Masking: An Account with Stated Assumptions
- Chapter 4 · Registers, the Two-Mass Model and Nonlinear Bifurcations
- Chapter 5 · The Auditory-Motor Loop: The Pitch-Shift Reflex, DIVA and Delayed State Estimation
- Chapter 6 · The Lombard Effect and Mixed Air- and Bone-Conducted Monitoring