What does Vocal Biomechanics and Auditory Feedback conclude, in numbers, about “The Lombard Effect and Mixed Air- and Bone-Conducted Monitoring”?
Answer: The Lombard effect is a robust, nearly automatic reflex: the louder the noise, the louder the voice, and the louder one hears oneself, the softer; instructions alone hardly suppress it, and feedback training is needed. A singer's own voice reaches the same cochlea by air and by bone (bone dominating at 1–2 kHz), and outside noise masks both. The illustrative calculation shows that with open ears in a loud band the own voice is 6–13 dB below the accompaniment, pitch estimation worsens and somatosensory weight rises; ear plugs restore the signal-to-noise ratio but leave the own voice heard almost entirely by bone; a monitor mix can restore the natural proportion of air and bone conduction. Isolation also makes singers sing more softly, lowering the voice-to-band ratio reaching the audience, a reliable direction whose size depends on assumptions. The next chapter leaves measurement behind to read some classical writing on singing and listening.
Scope of the numbers: Marked boxes separate published evidence, runnable Python calculations (16 programs, all checked), classical sources and the author's hypotheses.
Data table
The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python only
| SNR = own voice minus accompaniment at the cochlea (dB, 250 / 1k / 4k Hz); | |
| air = share of own voice arriving by air; sd in cents; w = weight on hearing | |
| condition | | 250 1k 4k | air | hear | w | fused |
| quiet room | +49.0 +54.1 +36.4 | | 62% | 2.7 | 0.99 | 2.7 |
| open ears, loud band | -13.0 | -5.9 -7.6 | 62% | 14.2 | 0.76 | 12.4 |
| foam ear plugs | +15.0 +15.0 +2.4 | | 2% | 2.9 | 0.99 | 2.9 |
| in-ear monitor -10 dB | +20.1 +20.1 +10.1 | | 12% | 2.8 | 0.99 | 2.7 |
| in-ear monitor +0 dB | +20.5 +21.2 +17.4 | | 35% | 2.7 | 0.99 | 2.7 |
| in-ear monitor +6 dB | +21.8 +23.5 +23.1 | | 60% | 2.7 | 0.99 | 2.7 |
Show the full program
# Hearing yourself through air and bone in loud accompaniment, band by band
# (illustrative). Air- (AC) and bone-conducted (BC) own voice add up in the SAME cochlea;
# outside noise masks both. Plugs cut AC voice and band by 20 dB and boost BC at low
# frequencies (occlusion); in-ear monitors isolate 25 dB and add the own voice back at mix
# gain m dB. Band pitch sd = 6 cents x (1 + 10^(-SNR/10)), combined by inverse variance,
# then fused with a noise-free laryngeal/vibrotactile sense (sd 25 cents, assumed).
import math
BANDS = (250, 500, 1000, 2000, 4000)
VOICE_AC = (78, 82, 80, 74, 66) # own voice by air, open ear
# bone path relative to air (BC dominant at 1-2 kHz)
BC_RE_AC = (-6, -3, 2, 3, -10)
OCCL = (15, 10, 3, 0, 0) # occlusion boost of the bone path, ear shut
ORCH = (92, 94, 90, 82, 74) # loud band at the singer's ear
SD_SOMA = 25.0
db_sum = lambda *ls: 10 * math.log10(sum(10 ** (v / 10) for v in ls))
def condition(kind, mix=0.0):
rows = []
for i in range(len(BANDS)):
ac, bc, noise = VOICE_AC[i], VOICE_AC[i] + BC_RE_AC[i], ORCH[i]
if kind == "quiet":
noise = 30.0
elif kind in ("plugs", "iem"):
cut = 20 if kind == "plugs" else 25
ac, noise, bc = ac - cut, noise - cut, bc + OCCL[i]
if kind == "iem":
ac = db_sum(ac, VOICE_AC[i] + mix) # monitor feed of the own voice
rows.append((db_sum(ac, bc) - noise, 1 / (1 + 10 ** ((bc - ac) / 10))))
sds = [6.0 * (1 + 10 ** (-snr / 10)) for snr, _ in rows]
sd_aud = 1 / math.sqrt(sum(1 / s ** 2 for s in sds))
prec = 1 / sd_aud ** 2 + 1 / SD_SOMA ** 2
return rows, sd_aud, (1 / sd_aud ** 2) / prec, 1 / math.sqrt(prec)
print("SNR = own voice minus accompaniment at the cochlea (dB, 250 / 1k / 4k Hz);")
print("air = share of own voice arriving by air; sd in cents; w = weight on hearing")
print("condition | 250 1k 4k | air | hear | w | fused")
CASES = (("quiet room", "quiet", 0), ("open ears, loud band", "open", 0),
("foam ear plugs", "plugs", 0), ("in-ear monitor -10 dB", "iem", -10),
("in-ear monitor +0 dB", "iem", 0), ("in-ear monitor +6 dB", "iem", 6))
for name, kind, mix in CASES:
rows, sd_aud, w, sd_f = condition(kind, mix)
snrs = " ".join(f"{rows[i][0]:+5.1f}" for i in (0, 2, 4))
air = sum(a for _, a in rows) / len(rows)
print(f"{name:22s}| {snrs} | {air:4.0%} | {sd_aud:5.1f} | {w:.2f} | {sd_f:5.1f}")Single source and citation
Fan, Y. (2026). Vocal Biomechanics, Non-Linear Source-Filter Coupling and Auditory-Motor Feedback (Version 1.0.0), Chapter 6: The Lombard Effect and Mixed Air- and Bone-Conducted Monitoring. 5D Library. https://doi.org/10.5281/zenodo.23770084
DOI: 10.5281/zenodo.23770084 · Read the monograph · 5DL-B-029 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026029,
author = {Fan, Yafu},
title = {Vocal Biomechanics, Non-Linear Source-Filter Coupling and Auditory-Motor Feedback},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
doi = {10.5281/zenodo.23770084},
url = {https://doi.org/10.5281/zenodo.23770084}
}Other chapter answers in this book
- Chapter 1 · Why the Vocal Folds Vibrate by Themselves: Phase Difference and Threshold Pressure
- Chapter 2 · Nonlinear Source–Filter Coupling: Inertance, Compliance and the Semi-Occluded Tract
- Chapter 3 · The Singer's Formant and Orchestral Masking: An Account with Stated Assumptions
- Chapter 4 · Registers, the Two-Mass Model and Nonlinear Bifurcations
- Chapter 5 · The Auditory-Motor Loop: The Pitch-Shift Reflex, DIVA and Delayed State Estimation
- Chapter 8 · Practice and a Pre-Registered Trial