What does Vocal Biomechanics and Auditory Feedback conclude, in numbers, about “Nonlinear Source–Filter Coupling: Inertance, Compliance and the Semi-Occluded Tract”?
Answer: Linear source–filter theory assumes that the source is unaffected by the tract, which holds when glottal impedance far exceeds tract impedance; with a narrow epilarynx the two become comparable and nonlinear interaction appears. Titze (2008) divides it into a level that drives the airflow and a level that drives the folds. Below its first formant the tract is inertive, and inertance puts the pressure above the glottis in step with fold motion, lowering the threshold pressure (by about a third in the sketch), while a compliant load raises it. Bifurcations are more frequent when F0 crosses F1, but "voice breaks" are chiefly a laryngeal register mechanism, with acoustic loading as one factor. A straw lowers the first resonance to about 200 Hz, changes the reactance region in which each harmonic falls and creates back pressure; consistent evidence for its practical effects is still lacking. The next chapter returns to the singer's formant of Volume 10 and does the signal-to-noise accounting under stated assumptions.
Scope of the numbers: Marked boxes separate published evidence, runnable Python calculations (16 programs, all checked), classical sources and the author's hypotheses.
Data table
The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 10
| straw 14 cm long, flow 0.15 L/s (soft sustained tone): | |
| inner diameter | mouth pressure | transglottal | Reynolds number | |
| 8 mm | | 0.09 cm H2O | 9.91 cm H2O | 1471 |
| 6 mm | | 0.29 cm H2O | 9.71 cm H2O | 1961 |
| 4 mm | | 1.46 cm H2O | 8.54 cm H2O | 2942 |
| 3 mm | | 4.61 cm H2O | 5.39 cm H2O | 3923 |
| resonance tube 27 cm x 9 mm (tube phonation) | 0.08 cm H2O before any water |
| adding water at the tube tip (depth below the surface): | |
| 2 cm deep: + 2.0 static -> mouth | 2.1, transglottal 7.9 cm H2O |
| 5 cm deep: + 5.0 static -> mouth | 5.1, transglottal 4.9 cm H2O |
| 10 cm deep: +10.0 static -> mouth 10.1, transglottal -0.1 cm H2O | |
| (below a typical onset pressure: lung pressure must rise) | |
| note: bubbling adds a pressure ripple at a few to tens of Hz (not modelled here) |
Show the full program
# Mouth back pressure during straw phonation, and the extra pressure with the tip in
# water. Straw: Poiseuille friction + kinetic loss of the exit jet (a rough engineering
# estimate):
# dP = 8 mu L U / (pi r^4) + rho U^2 / (2 A^2); water: dP_w = rho_w g h
# Transglottal pressure (lung minus mouth) drives the folds; lung pressure held at 10 cm
# H2O. Flows and sizes are illustrative.
import math
RHO, MU, RHO_W, G = 1.14, 1.85e-5, 1000.0, 9.81
CM = 98.07 # Pa per cm H2O
P_LUNG = 10.0 # cm H2O
def straw_dp(flow_lps, length_m, diam_m):
u = flow_lps / 1000.0
r, area = diam_m / 2, math.pi * diam_m ** 2 / 4
lam = 8 * MU * length_m * u / (math.pi * r ** 4)
kin = RHO * u * u / (2 * area * area)
re = RHO * (u / area) * diam_m / MU
return (lam + kin) / CM, re
print("straw 14 cm long, flow 0.15 L/s (soft sustained tone):")
print(" inner diameter | mouth pressure | transglottal | Reynolds number")
for d_mm in (8.0, 6.0, 4.0, 3.0):
dp, re = straw_dp(0.15, 0.14, d_mm / 1000)
print(f" {d_mm:3.0f} mm | {dp:5.2f} cm H2O | {P_LUNG - dp:5.2f} cm H2O"
f" | {re:6.0f}")
dp, _ = straw_dp(0.15, 0.27, 0.009)
print(f"resonance tube 27 cm x 9 mm (tube phonation): {dp:.2f} cm H2O before any water")
print("adding water at the tube tip (depth below the surface):")
for h_cm in (2, 5, 10):
pw = RHO_W * G * h_cm / 100 / CM
tg = P_LUNG - dp - pw
print(f" {h_cm:2d} cm deep: +{pw:4.1f} static -> mouth {dp + pw:4.1f}, "
f"transglottal {tg:4.1f} cm H2O")
if tg < 3:
print(" (below a typical onset pressure: lung pressure must rise)")
print("note: bubbling adds a pressure ripple at a few to tens of Hz (not modelled here)")Single source and citation
Fan, Y. (2026). Vocal Biomechanics, Non-Linear Source-Filter Coupling and Auditory-Motor Feedback (Version 1.0.0), Chapter 2: Nonlinear Source–Filter Coupling: Inertance, Compliance and the Semi-Occluded Tract. 5D Library. https://doi.org/10.5281/zenodo.23770084
DOI: 10.5281/zenodo.23770084 · Read the monograph · 5DL-B-029 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026029,
author = {Fan, Yafu},
title = {Vocal Biomechanics, Non-Linear Source-Filter Coupling and Auditory-Motor Feedback},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
doi = {10.5281/zenodo.23770084},
url = {https://doi.org/10.5281/zenodo.23770084}
}Other chapter answers in this book
- Chapter 1 · Why the Vocal Folds Vibrate by Themselves: Phase Difference and Threshold Pressure
- Chapter 3 · The Singer's Formant and Orchestral Masking: An Account with Stated Assumptions
- Chapter 4 · Registers, the Two-Mass Model and Nonlinear Bifurcations
- Chapter 5 · The Auditory-Motor Loop: The Pitch-Shift Reflex, DIVA and Delayed State Estimation
- Chapter 6 · The Lombard Effect and Mixed Air- and Bone-Conducted Monitoring
- Chapter 8 · Practice and a Pre-Registered Trial