What does Interoceptive Decoupling and Autonomic Restoration conclude, in numbers, about “Interoception and Precision: The First Link Runs Backwards”?
Answer: Interoception has well-described anatomical pathways, and writing it as precision-weighted inference is a productive framework. But the framework's first expression refutes the first link of the original claim: lowering the precision of the interoceptive channel pushes the posterior toward the prior, so it lowers the estimate of bodily threat only when the prior is benign, and raises it when the prior is alarmed (program p01: from 2.333 to 2.800). Bringing the estimate down requires moving the prior, which is a different operation from declining to interpret, and about seventeen times more costly in distributional terms. The two-level model shows that what "decoupling" amounts to is the situation estimate ceasing to track the bodily estimate, not the bodily signal disappearing, and that it simultaneously makes the situation estimate slower (time constant from 0.688 s to 1.886 s). Finally, the measurement of interoception has unsolved problems of its own: heartbeat counting scores cannot be taken as interoceptive accuracy, and self-report scales measure a different construct from objective performance; Chapter 8 chooses its outcomes accordingly.
Scope of the numbers: Marked boxes separate published evidence, runnable Python calculations (16 programs), classical sources and the author's models and hypotheses; apart from cited literature data, all data in the book are synthetic.
Data table
The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 2.333, 2.800
| A. benign prior (mu_prior | 0): lowering sensory precision helps |
| pi_sense mu_post sd_post |mu_post| vs signal | |
| 4.00 | 1.600 0.447 80% of the signal |
| 2.00 | 1.333 0.577 67% of the signal |
| 1.00 | 1.000 0.707 50% of the signal |
| 0.50 | 0.667 0.816 33% of the signal |
| 0.25 | 0.400 0.894 20% of the signal |
| B. alarmed prior (mu_prior | 3): the SAME move makes the estimate worse |
| pi_sense mu_post sd_post |mu_post| vs signal | |
| 4.00 | 2.200 0.447 110% of the signal |
| 2.00 | 2.333 0.577 117% of the signal |
| 1.00 | 2.500 0.707 125% of the signal |
| 0.50 | 2.667 0.816 133% of the signal |
| 0.25 | 2.800 0.894 140% of the signal |
| C. what has to change for the posterior to come down: | |
| baseline (alarmed prior, pi_sense 2): mu_post | 2.333 |
| halve sensory precision mu_post = +2.500 (+0.167) | |
| halve PRIOR precision mu_post = +2.200 (-0.133) | |
| move the prior to 0 mu_post = +1.333 (-1.000) | |
| move prior to 0 AND halve its precision mu_post = +1.600 (-0.733) | |
| D. cost of the shift, KL from the alarmed to the revised posterior (nats): | |
| halve sensory precision | 0.0889 |
| move the prior to 0 | 1.5000 |
Key formula
Show the full program
# Chapter 1. Interoceptive inference as precision-weighted cue combination.
# Two Gaussian sources, a prior (expected bodily state) and an interoceptive
# signal, combine into a posterior whose precision is the sum of the two
# precisions:
# pi_post = pi_prior + pi_sense, mu_post = (pi_prior mu_prior + pi_sense y)
# / pi_post.
# "Turning down the precision of the interoceptive channel" therefore moves
# the posterior TOWARD THE PRIOR and shrinks posterior variance less; it does
# not by itself make the posterior benign. This is the dark-room objection in
# one line: if the prior is itself alarming, lowering sensory precision makes
# the estimate MORE alarming, not less. All numbers are dimensionless
# illustrative units.
import math
def combine(mu_prior, pi_prior, y, pi_sense):
pi_post = pi_prior + pi_sense
mu_post = (pi_prior * mu_prior + pi_sense * y) / pi_post
return mu_post, pi_post
def kl_gauss(m1, p1, m0, p0):
"""KL( N(m1,1/p1) || N(m0,1/p0) ) in nats."""
return 0.5 * (math.log(p1 / p0) + p0 / p1 + p0 * (m1 - m0) ** 2 - 1.0)
if __name__ == "__main__":
# an interoceptive signal 2 units from the benign set point
Y = 2.0
print("A. benign prior (mu_prior = 0): lowering sensory precision helps")
print(" pi_sense mu_post sd_post |mu_post| vs signal")
for pi_s in (4.0, 2.0, 1.0, 0.5, 0.25):
m, p = combine(0.0, 1.0, Y, pi_s)
print(" {:8.2f} {:9.3f} {:9.3f} {:5.0f}% of the signal"
.format(pi_s, m, 1 / math.sqrt(p), 100 * m / Y))
print(
"\nB. alarmed prior (mu_prior = 3): the SAME move makes the estimate"
" worse"
)
print(" pi_sense mu_post sd_post |mu_post| vs signal")
for pi_s in (4.0, 2.0, 1.0, 0.5, 0.25):
m, p = combine(3.0, 1.0, Y, pi_s)
print(" {:8.2f} {:9.3f} {:9.3f} {:5.0f}% of the signal"
.format(pi_s, m, 1 / math.sqrt(p), 100 * m / Y))
print("\nC. what has to change for the posterior to come down:")
base_m, base_p = combine(3.0, 1.0, Y, 2.0)
print(
" baseline (alarmed prior, pi_sense 2): mu_post = {:.3f}".format(
base_m
)
)
for lab, args in (
("halve sensory precision", (3.0, 1.0, Y, 1.0)),
("halve PRIOR precision", (3.0, 0.5, Y, 2.0)),
("move the prior to 0", (0.0, 1.0, Y, 2.0)),
("move prior to 0 AND halve its precision", (0.0, 0.5, Y, 2.0)),
):
m, p = combine(*args)
print(
" {:42s} mu_post = {:+.3f} ({:+.3f})".format(
lab, m, m - base_m
)
)
print(
"\nD. cost of the shift, KL from the alarmed to the revised posterior"
" (nats):"
)
for lab, args in (("halve sensory precision", (3.0, 1.0, Y, 1.0)),
("move the prior to 0", (0.0, 1.0, Y, 2.0))):
m, p = combine(*args)
print(" {:42s} {:.4f}".format(lab, kl_gauss(m, p, base_m, base_p)))Single source and citation
Fan, Y. (2026). Interoceptive Decoupling, Salience-Network Switching and Autonomic Visceral Restoration (Version 1.0.0), Chapter 1: Interoception and Precision: The First Link Runs Backwards. 5D Library. https://doi.org/10.5281/zenodo.24020418
DOI: 10.5281/zenodo.24020418 · Read the monograph · 5DL-B-053 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026053,
author = {Fan, Yafu},
title = {Interoceptive Decoupling, Salience-Network Switching and Autonomic Visceral Restoration},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
doi = {10.5281/zenodo.24020418},
url = {https://doi.org/10.5281/zenodo.24020418}
}Other chapter answers in this book
- Chapter 2 · Switching Between Networks: Dwell Time and Its Cost
- Chapter 3 · The Non-Judgmental Imagery Stream: Trading Errors, Not Gaining Information
- Chapter 4 · Two Autonomic Outflows: The Vagus Does Not Reach the Pelvis
- Chapter 5 · How Much Can Blood Flow Change: The Fourth Power and Autoregulation
- Chapter 6 · The Composite Model, Non-Identifiability and Case Evidence
- Chapter 8 · Practice and a Pre-Registered Test