Preface. Three Claims About Rhythmic Sound
Note
This book is not medical, hearing-care or sleep-treatment advice and recommends no audio product. Please read this first. It studies the parts of rhythmic acoustic stimulation that arithmetic can test: where the envelope of a binaural beat or an isochronic tone actually is, how long an auditory steady-state response must be recorded before it can be seen, how pink noise is synthesised and how it reads on an A-weighted meter, how a masking sound changes the micro-arousals caused by night-time noise events, and the hearing dose of an audio track. Its phase-locking curves, response amplitudes, EEG noise levels and arousal probabilities are illustrative model parameters, not data from any listener or product; the direction of each result comes from acoustics and statistics, the exact numbers move with the parameters.
Most rhythmic audio on the market rests on three claims. First, that a binaural beat makes the EEG “follow” the beat frequency and so carries the brain into a chosen state. Second, that certain fixed pure tones (432 Hz or 528 Hz, for instance) “resonate” with brain waves by themselves, or even repair DNA. Third, that pink noise and tracks at the 7.83 Hz “Schumann resonance” deepen sleep. This book turns the three claims into runnable programs and tests them one by one.
As in the other works of 5D Library, the book first tries to refute, then states the limits, and reports negative results as they are.
What the book contains
Chapter 1 computes, with Hilbert envelopes, the modulation depth that a binaural beat and an isochronic tone deliver to each ear, and explains why binaural beats depend on the phase locking of the auditory nerve to the carrier. Chapter 2 draws the Arnold tongue of Adler’s equation and computes how the signal-to-noise ratio of an auditory steady-state response grows with recording time. Chapter 3 synthesises pink noise, checks its slope per octave, and discusses sleep masking with A-weighting and an illustrative arousal model. Chapter 4 covers delivery routes (insert earphones, bone conduction, loudspeakers) and the gating shape of isochronic tones. Chapter 5 computes hearing dose and puts the Schumann resonance back on its physical scale. Chapter 6 turns to evidence: detection power in a single recording, placebo and sample size, multiple comparisons. Chapter 7 reads Shen Kuo’s Mengxi Bitan on the sixteen pitches, the comma of the sanfen sunyi method, Zhu Zaiyu’s equal temperament and Helmholtz on combination tones, and summarises the pitch-pipe legend of the Lüshi Chunqiu. Chapter 8 gives a ten-flag audit and a pre-registered crossover trial.
Claims corrected after checking
- The envelope of a binaural beat is in neither ear. Through headphones each ear receives a steady tone with no envelope, of modulation depth 0.0000; the beat appears only after the brainstem compares the phases of the two ears. Mixed in the air, the same two tones become an ordinary monaural beat of depth 1.0000 (p01).
- The binaural drive fades quickly as the carrier rises. Under this book’s illustrative phase-locking curve, an isochronic tone already drives 17.6 dB more power than a binaural beat on a 400 Hz carrier, and 84.4 dB more at 2,000 Hz (p02).
- A static pure tone has no rhythm to follow. A 432 Hz or 528 Hz tone has envelope depth 0 and drive 0; its wavelength in water is more than a billion times the width of DNA (p01, p04).
- The “Schumann resonance” and a 7.83 Hz track share a number and nothing else. The resonance is an electromagnetic mode between Earth and the ionosphere, with a magnetic field about fifty million times weaker than the static geomagnetic field; sound is a pressure wave, and the two share no mechanism (p10).
- Pink noise works by masking, not by its frequencies as such. A masker raises the background, shrinks the emergence of noise events and so lowers the chance that each event causes a micro-arousal; the price is extra sound energy all night (p06).
How to read the boxes
Boxes mark published evidence, runnable Python computations (16 programs, standard library only, fixed random seeds; each is run at build time and its real output printed below it), classical sources, notes and the author’s hypotheses; every hypothesis states what result would show it wrong. To keep code intact in print, the programs and their output use ASCII only; terms and pitch names appear in English or pinyin, as listed below.
Note
Code key: binaural, monaural and isochronic beats; envelope; depth (modulation depth); carrier; VS (vector strength, the degree of phase locking); drive; PLV (phase locking value); ASSR (auditory steady-state response); IA (interaural attenuation); splatter (spectral spread); crest (crest factor); dBA (A-weighted level); dose (hearing dose); sham (sham stimulus); FWER (family-wise error rate); Holm (Holm’s step-down correction). Pitch names: huangzhong, dalv, taicu, jiazhong, guxian, zhonglv, ruibin, linzhong, yize, nanlv, wuyi, yingzhong; qing marks the upper-octave notes.
Disclosure
The author uses the works of 5D Library, including this book, as the methodological basis of his community courses, the 5D Ascension Cards (Dimensional Shift Card Decks) and the Yafu AI knowledge base, and develops and runs paid online software, courses and AI products on traditional divinatory and mind-body themes; the models of this book can be applied directly to judge the sound and sleep content of such products, so he has a direct commercial interest in its subject. The book promotes no software, course, card deck, audio or service, uses no user or sales data from the author’s businesses, and accepts no sponsorship. All its models are offered for mathematical study and teaching only and constitute no medical, hearing-care, sleep-treatment, investment or other business advice. The trial in Chapter 8 must be carried out with pre-registered code by an independent analyst who has no financial relationship with the author, and its results will be published whether positive or negative.
Fan, Y. (2026). Rhythmic Acoustic Stimulation, Auditory Steady-State Responses and Modulation Signal Engineering: Binaural versus Isochronic Envelope Depth, 40-Hz Phase-Locking Bounds and Pink-Noise Spectral Masking [节律声刺激、听觉稳态反应与双耳等时调制工程] (Version 1.0.0). 5D Library. https://doi.org/10.5281/zenodo.24090211 · Licensed under Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0).