What does Room Modes and Bass Dead Spots conclude, in numbers, about “Low-Frequency Dead Spots: Modal Sums, Seat Maps and Several Subwoofers”?

Answer: Chapter 4 computes the bass response at the main seat by modal summation: the standard deviation is 14.4 dB with the subwoofer at the centre of the floor and 10.5 dB in a corner, and one unit at each wall middle lowers the seat-to-seat spread to 0.7 dB at a cost of 8.8 dB in output.

Scope of the numbers: Its rooms, absorption coefficients, reverberation times, positions and listening habits are illustrative parameters; all calculations are generated by its programs. It is not medical advice, claims no effect, judges no one's hearing, and asks readers to consult a licensed physician before any self-experiment.

中文版

Data table

The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 10.5, 14.4

seat (2.6, 1.7, 1.1) m, T = 0.51 s, B = 4.31 Hz, 25 to 120 Hz
sourcemean dBsd dBmax-mindeepest dipat Hz
front corner0.010.534.3-26.254.5
front wall middle-1.58.328.8-21.754.0
floor centre-0.814.442.9-33.439.5
(mean dB relative to the front corner; sd about the energy mean)

Key formula

\[p(r, f)\propto f\sum_n\frac{\psi_n(r_s)\,\psi_n(r)}{\Lambda_n\,(f_n^2 - f^2 + j f B)}\]
Show the full program
# Chapter 4. p41: the bass response at one seat, built mode by mode.
# Modal sum for a small point source of constant volume velocity:
#   p(r, f) ~ f * sum_n psi_n(rs) psi_n(r) / (L_n (fn^2 - f^2 + j f B))
# with psi_n the cosine shapes of p12, L_n the mean of psi_n^2 over the
# room (1/2 per non-zero index) and B = 3 ln(10) / (pi T) the modal
# bandwidth of p32. All modes up to 400 Hz are kept, (0,0,0) included.
# Study of p11 furnished, T = 0.51 s (p31); seat 2.6 m from the front
# wall on the centre line, ears 1.1 m high; sources 0.2 m from surfaces.
# Positions and T are illustrative.
import itertools
import math

C = 343.0
ROOM = (4.2, 3.4, 2.7)
T60 = 0.51
B = 3.0 * math.log(10.0) / (math.pi * T60)
SEAT = (2.6, 1.7, 1.1)
SOURCES = [("front corner", (0.2, 0.2, 0.2)),
           ("front wall middle", (0.2, 1.7, 0.2)),
           ("floor centre", (2.1, 1.7, 0.2))]
FREQS = [25.0 + 0.5 * i for i in range(191)]


def modes(room, fmax, c=C):
    top = [int(2.0 * fmax * d / c) + 1 for d in room]
    out = []
    for n in itertools.product(*[range(t + 1) for t in top]):
        f = 0.5 * c * math.hypot(*[k / d for k, d in zip(n, room)])
        if f <= fmax:
            out.append((f, n))
    return sorted(out)


def psi(n, r):
    return math.prod(math.cos(k * math.pi * x / d)
                     for k, x, d in zip(n, r, ROOM))


MODES = modes(ROOM, 400.0)


def response(src, seat, freqs=FREQS):
    w = [(fn, psi(n, src) * psi(n, seat) / 0.5 ** len([k for k in n if k]))
         for fn, n in MODES]
    out = []
    for f in freqs:
        terms = [g / complex(fn * fn - f * f, f * B) for fn, g in w]
        re_part = math.fsum(z.real for z in terms)
        im_part = math.fsum(z.imag for z in terms)
        out.append(20.0 * math.log10(f * math.hypot(re_part, im_part)))
    return out


def energy_mean(levels):
    return 10.0 * math.log10(math.fsum(10.0 ** (x / 10.0) for x in levels)
                             / len(levels))


ref = None
print("seat (%.1f, %.1f, %.1f) m, T = %.2f s, B = %.2f Hz, 25 to 120 Hz"
      % (SEAT + (T60, B)))
print("  source             mean dB  sd dB  max-min  deepest dip  at Hz")
for name, src in SOURCES:
    lv = response(src, SEAT)
    mean = energy_mean(lv)
    if ref is None:
        ref = mean
    sd = math.sqrt(math.fsum((x - mean) ** 2 for x in lv) / len(lv))
    low = min(lv)
    print("  %-17s %8.1f %6.1f %8.1f %12.1f %6.1f"
          % (name, mean - ref, sd, max(lv) - low, low - mean,
             FREQS[lv.index(low)]))
print("(mean dB relative to the front corner; sd about the energy mean)")

Single source and citation

Fan, Y. (2026). Room-Acoustic Standing-Wave Modes, Low-Frequency Dead Spots, Listening Dose and the Physics of Binaural Beats (Version 1.0.0), Chapter 4: Low-Frequency Dead Spots: Modal Sums, Seat Maps and Several Subwoofers. 5D Library. DOI pending

DOI pending · monograph page goes live after publication · 5DL-B-288 · v1.0.0 · CC-BY-NC-ND-4.0

BibTeX
@book{fan2026288,
  author    = {Fan, Yafu},
  title     = {Room-Acoustic Standing-Wave Modes, Low-Frequency Dead Spots, Listening Dose and the Physics of Binaural Beats},
  year      = {2026},
  publisher = {5D Library},
  edition   = {1.0.0},
  note      = {DOI pending}
}

Other chapter answers in this book