What does Soil Couples, Copper Antennas and Electroculture Trials conclude, in numbers, about “Practice and Falsification: A Farm Owner's Checklist, a Copy Checker and a Pre-Registered Split-Plot Trial”?
Answer: Chapter 8 gives an operator's checklist, a copy checker and a pre-registered split-plot protocol: detecting a gain of a tenth needs about 5320 square metres. Marked boxes separate published evidence, runnable Python calculations (18 programs), classical sources and the author's hypotheses.
Scope of the numbers: Its parameters are illustrative; all calculations are generated by its programs; the book is not agronomic or investment advice and judges no brand. Chapter 1 uses the Nernst equation to find an open-circuit voltage of about 1.0734 volts for a copper-zinc couple in an illustrative soil solution and shows that its energy comes from corroding zinc.
Data table
The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 5320
| effect | blocks | t crit | power | plots | area m2 |
| 10% | 6 | 2.571 | 0.4015 | 36 | 2280 |
| 10% | 8 | 2.365 | 0.5445 | 48 | 3040 |
| 10% | 10 | 2.262 | 0.6680 | 60 | 3800 |
| 10% | 12 | 2.201 | 0.7570 | 72 | 4560 |
| 10% | 14 | 2.160 | 0.8375 | 84 | 5320 |
| 10% | 16 | 2.131 | 0.8840 | 96 | 6080 |
| 5% | 32 | 2.040 | 0.6275 | 192 | 12160 |
| 5% | 40 | 2.023 | 0.7300 | 240 | 15200 |
| 5% | 44 | 2.017 | 0.7795 | 264 | 16720 |
| 5% | 48 | 2.012 | 0.8195 | 288 | 18240 |
| 5% | 56 | 2.004 | 0.8880 | 336 | 21280 |
| SD of a block difference in main-plot means: 0.1178 | |||||
| effect 10%: normal formula 10.9 blocks; simulated power 0.8 at 14 | |||||
| effect 5%: normal formula 43.5 blocks; simulated power 0.8 at 48 |
Show the full program
# Chapter 8. p81: sample size for the pre-registered split-plot trial.
# Main plots: rod or no rod; subplots: no zinc, zinc salt matched to
# the galvanic release of p52, double zinc. The rod effect is tested
# on main-plot means with r - 1 degrees of freedom (a paired t test
# on block differences, identical to F(1, r-1)). Effect to detect
# as below; main-plot SD 0.08 and subplot SD 0.04 (illustrative).
# Effects of 10 and 5 percent; power by fixed-seed Monte Carlo, 2000
# trials per row; 2.8016 = 1.9600 + 0.8416 for the normal formula.
# Field area uses 5 m x 6 m subplots and the 4 m guard strip of p63.
import math
import random
import statistics
def betacf(a, b, x):
qab, qap, qam = a + b, a + 1.0, a - 1.0
c, d = 1.0, 1.0 - qab * x / qap
d = 1.0 / (d if abs(d) > 1e-300 else 1e-300)
h = d
for m in range(1, 300):
m2 = 2 * m
for aa in (m * (b - m) * x / ((qam + m2) * (a + m2)),
-(a + m) * (qab + m) * x / ((a + m2) * (qap + m2))):
d = 1.0 + aa * d
d = 1.0 / (d if abs(d) > 1e-300 else 1e-300)
c = 1.0 + aa / c
c = c if abs(c) > 1e-300 else 1e-300
h *= d * c
if abs(d * c - 1.0) < 1e-14:
break
return h
def t_crit(df):
lo, hi = 0.0, 50.0
for _ in range(100):
t = (lo + hi) / 2.0
x = df / (df + t * t)
lb = (math.lgamma(df / 2.0 + 0.5) - math.lgamma(df / 2.0)
- math.lgamma(0.5) + df / 2.0 * math.log(x)
+ 0.5 * math.log(1.0 - x))
if x < (df / 2.0 + 1.0) / (df / 2.0 + 2.5):
up = 0.5 * math.exp(lb) * betacf(df / 2.0, 0.5, x) / (df / 2.0)
else:
up = 0.5 * (1.0 - math.exp(lb) * betacf(0.5, df / 2.0, 1.0 - x)
/ 0.5)
lo, hi = (t, hi) if up > 0.025 else (lo, t)
return (lo + hi) / 2.0
SW, SE, B = 0.08, 0.04, 3
rng = random.Random(20261112)
print("effect blocks t crit power plots area m2")
first = {}
for delta, grid in ((0.10, (6, 8, 10, 12, 14, 16)),
(0.05, (32, 40, 44, 48, 56))):
for r in grid:
crit = t_crit(r - 1)
hit = 0
for _ in range(2000):
d = []
for _ in range(r):
m1 = delta + rng.gauss(0.0, SW) + statistics.fmean(
rng.gauss(0.0, SE) for _ in range(B))
m0 = rng.gauss(0.0, SW) + statistics.fmean(
rng.gauss(0.0, SE) for _ in range(B))
d.append(m1 - m0)
t = statistics.fmean(d) / (statistics.stdev(d) / math.sqrt(r))
hit += abs(t) > crit
pw = hit / 2000
if pw >= 0.8 and delta not in first:
first[delta] = r
area = r * 2 * (B * 5.0 + 4.0) * (6.0 + 4.0)
print("{:5.0%} {:5d} {:6.3f} {:.4f} {:5d} {:7.0f}"
.format(delta, r, crit, pw, r * 2 * B, area))
sd_d = math.sqrt(2.0 * (SW ** 2 + SE ** 2 / B))
print("SD of a block difference in main-plot means: {:.4f}".format(sd_d))
for delta in (0.10, 0.05):
n = 2.8016 ** 2 * sd_d ** 2 / delta ** 2
print("effect {:.0%}: normal formula {:.1f} blocks; simulated power"
" 0.8 at {}".format(delta, n, first.get(delta)))Single source and citation
Fan, Y. (2026). Nernst Potentials in Soil Electrochemistry, Nanowatt Harvest Limits of Passive Copper Antennas and Field Block Designs for Electroculture Yield Claims (Version 1.0.0), Chapter 8: Practice and Falsification: A Farm Owner's Checklist, a Copy Checker and a Pre-Registered Split-Plot Trial. 5D Library. DOI pending
DOI pending · monograph page goes live after publication · 5DL-B-170 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026170,
author = {Fan, Yafu},
title = {Nernst Potentials in Soil Electrochemistry, Nanowatt Harvest Limits of Passive Copper Antennas and Field Block Designs for Electroculture Yield Claims},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
note = {DOI pending}
}Other chapter answers in this book
- Chapter 1 · The Nernst Equation: Open-Circuit Voltages of Copper-Zinc and Copper-Iron Couples in Soil Solution
- Chapter 2 · Internal Resistance, Oxygen Diffusion and the Maximum Power $V^2/4R$: What a Soil Couple Can Deliver
- Chapter 3 · Gauss's Law and Air Conductivity: How Much Current a Copper Rod Collects from the Fair-Weather Field
- Chapter 4 · Faraday's Law and Poynting's Theorem: What a Still Coil, the Geomagnetic Field and Radio Waves Can Give a Field
- Chapter 5 · The Energy Ledger: Electroculture Power as a Share of Photosynthetically Active Radiation, and Zinc as a Confounder
- Chapter 6 · Testing in the Field: Randomised Blocks, Split Plots, Power Analysis and Guard Strips
- Chapter 7 · Reading the Sources: Chen Fu's "Fitness of Terrain" and the Electroculture Trials of Lemström and Blackman