What does Cold Immersion and the Hypertrophy Penalty conclude, in numbers, about “A Skin-Fat-Core Cylinder: Finite Differences and Newton Cooling”?
Answer: Chapter 3 solves the heat-flow equation of a skin-fat-core cylinder: ten minutes of cold water draw some 210 kcal of heat, mostly stored heat that the surroundings can repay; the convective coefficients of water and air differ 25-fold, steady heat loss only 1.90-fold.
Scope of the numbers: Its parameters are illustrative; all calculations are generated by its programs; it is not medical advice, claims no health benefit, and asks readers to consult a licensed physician before any self-experiment. Chapter 5 derives a rule for the gap between training and cold water: with illustrative parameters a 6-hour gap cuts the interference to 0.135 of an immediate plunge, for a predicted growth ratio of 0.910.
Data table
The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 1.90, 25
| fat mm | medium | h | Bi | skin C | loss W | share tissue |
|---|---|---|---|---|---|---|
| 5 | still air | 10 | 0.25 | 25.2 | 273 | 0.438 |
| 5 | windy air | 25 | 0.62 | 19.2 | 412 | 0.661 |
| 5 | still water | 250 | 6.25 | 11.3 | 593 | 0.951 |
| 5 | stirred water | 500 | 12.50 | 10.7 | 607 | 0.975 |
| 10 | still air | 10 | 0.50 | 23.3 | 239 | 0.507 |
| 10 | windy air | 25 | 1.25 | 17.6 | 340 | 0.720 |
| 10 | still water | 250 | 12.50 | 11.0 | 454 | 0.963 |
| 10 | stirred water | 500 | 25.00 | 10.5 | 463 | 0.981 |
| 20 | still air | 10 | 1.00 | 20.7 | 192 | 0.605 |
| 20 | windy air | 25 | 2.50 | 15.6 | 252 | 0.793 |
| 20 | still water | 250 | 25.00 | 10.7 | 310 | 0.975 |
| 20 | stirred water | 500 | 50.00 | 10.3 | 313 | 0.987 |
| still water / still air: h ratio 25, loss ratio 1.90 |
Show the full program
# Chapter 3. p32: Water versus air under Newton's law of cooling.
# Steady state, planar approximation of the p31 shell: series thermal
# resistances per square metre, skin 2 mm (k 0.37), fat F mm (k 0.20),
# vasoconstricted muscle shell 20 mm (k 0.42), then 1/h at the surface.
# Core 37 C, medium 10 C, surface 1.8 m2. Convective coefficients are
# textbook orders of magnitude (illustrative): still air 10, wind 25,
# still water 250, stirred water 500 W/m2K. Bi = h * F / k_fat.
# The point: h differs 25-fold between still water and still air, but
# steady loss differs far less, because fat and muscle are in series.
# 中文注:牛顿冷却边界与组织串联热阻,比较水与空气。
import math
AREA, T_CORE, T_ENV = 1.8, 37.0, 10.0
MEDIA = (("still air", 10.0), ("windy air", 25.0),
("still water", 250.0), ("stirred water", 500.0))
def tissue_r(fat_mm):
parts = [0.002 / 0.37, fat_mm / 1000.0 / 0.20, 0.020 / 0.42]
return math.fsum(parts)
print("fat mm medium h Bi skin C loss W share tissue")
for fat in (5, 10, 20):
rt = tissue_r(fat)
for name, h in MEDIA:
rtot = rt + 1.0 / h
flux = (T_CORE - T_ENV) / rtot
skin = T_ENV + flux / h
print("{:5d} {:13s} {:5.0f} {:6.2f} {:7.1f} {:7.0f} {:9.3f}"
.format(fat, name, h, h * fat / 1000.0 / 0.20, skin,
flux * AREA, rt / rtot))
r10 = tissue_r(10)
ratio = (1.0 / (r10 + 1.0 / 10.0)) / (1.0 / (r10 + 1.0 / 250.0))
print("still water / still air: h ratio {:.0f}, loss ratio {:.2f}"
.format(250.0 / 10.0, 1.0 / ratio))Single source and citation
Fan, Y. (2026). Cold-Immersion Heat-Flow Equations, Brown-Fat Non-Shivering Thermogenesis and the Post-Training Cryotherapy Hypertrophy Penalty (Version 1.0.0), Chapter 3: A Skin-Fat-Core Cylinder: Finite Differences and Newton Cooling. 5D Library. DOI pending
DOI pending · monograph page goes live after publication · 5DL-B-183 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026183,
author = {Fan, Yafu},
title = {Cold-Immersion Heat-Flow Equations, Brown-Fat Non-Shivering Thermogenesis and the Post-Training Cryotherapy Hypertrophy Penalty},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
note = {DOI pending}
}Other chapter answers in this book
- Chapter 1 · The Post-Training Ice-Bath Penalty: One Trial and Two Pooled Analyses
- Chapter 2 · The Fat-Burning Ledger: One Cold Plunge Is Worth a Few Dozen Kilocalories
- Chapter 4 · Brown-Fat Non-Shivering Thermogenesis: a Power Ceiling and a Critical Water Temperature
- Chapter 5 · A Suppression Function for the Training-to-Cold Gap, with a Sensitivity Scan
- Chapter 6 · Cooling Dose, Residual Muscle Cooling and the Core Safety Margin
- Chapter 7 · Classical Sources East and West: Winter Storing in the Suwen and Seneca's New Year Plunge
- Chapter 8 · Closing the Loop: the Cold-and-Heat Bath Scheduler and a Pre-Registered A-B-A Test