5D Library › Singer Formant Clustering, Glottal Closure Quotients and Acoustic Authority Psychophysics · 中文

Chapter 8. Practice: A Measurement Protocol for an Authority Voice Diagnostic

Note

Not a medical or clinical tool. This chapter outlines how voice measures could be collected for coaching and discussion. Jitter, shimmer and closed quotient are also used in clinical voice assessment; hoarseness lasting more than a few weeks should be examined by a physician. The parameters in this chapter are illustrative.

Which measures are repeatable

A diagnostic that reports one number per person must first show that the number is stable from day to day. p14 uses illustrative between-person and within-person standard deviations to compute reliability (the intraclass correlation (Shrout and Fleiss 1979)) and the smallest detectable change.

Calculation

# Chapter 8. p14: How repeatable are the measures? Illustrative between-
# person and within-person (day-to-day) standard deviations. Reliability
# ICC = b^2 / (b^2 + w^2); the smallest change in one person that is
# larger than day-to-day noise with 95% confidence is MDC = 1.96 *
# sqrt(2) * w. A study of 40 persons measured on two days estimates the
# ICC; its 10% to 90% range over 2,000 such studies is shown. Seed 99.
import random
from math import sqrt

MEASURES = (("mean F0 (st)", 2.5, 0.8), ("jitter %", 0.15, 0.12),
            ("shimmer %", 0.8, 0.7), ("pause ratio", 0.05, 0.04),
            ("final slope st/s", 5.0, 6.0))

def icc(pairs):
    n = len(pairs)
    m = sum(a + b for a, b in pairs) / (2 * n)
    msb = 2 * sum(((a + b) / 2 - m) ** 2 for a, b in pairs) / (n - 1)
    msw = sum((a - b) ** 2 / 2 for a, b in pairs) / n
    return (msb - msw) / (msb + msw)

if __name__ == "__main__":
    rng = random.Random(99)
    print("   measure            ICC    MDC      study ICC 10% to 90%")
    for name, b, w in MEASURES:
        est = []
        for _ in range(2000):
            pairs = []
            for _ in range(40):
                t = rng.gauss(0, b)
                pairs.append((t + rng.gauss(0, w), t + rng.gauss(0, w)))
            est.append(icc(pairs))
        est.sort()
        print("   {:<16}  {:5.2f}  {:6.2f}   {:6.2f} to {:5.2f}".format(
            name, b * b / (b * b + w * w), 1.96 * sqrt(2) * w,
            est[200], est[1800]))
#    measure            ICC    MDC      study ICC 10% to 90%
#    mean F0 (st)       0.91    2.22     0.87 to  0.94
#    jitter %           0.61    0.33     0.46 to  0.72
#    shimmer %          0.57    1.94     0.40 to  0.69
#    pause ratio        0.61    0.11     0.47 to  0.72
#    final slope st/s   0.41   16.63     0.23 to  0.57

Mean pitch is highly repeatable (0.91), with a smallest detectable change of 2.22 semitones. Jitter and pause ratio are moderate (0.61), shimmer lower (0.57), and the final slope poor (0.41): a single day’s slope must change by 16.63 st/s before the change exceeds day-to-day noise. A study of 40 persons estimates these reliabilities with wide ranges (0.23 to 0.57 for the slope), so a diagnostic should publish its own test-retest data.

Where to put the microphone

p15 places a voice of 70 dB at 0.3 m in a typical meeting room.

Calculation

# Chapter 8. p15: Where to put the microphone. A voice of 70 dB at 0.3 m
# (direct sound falls 6 dB per doubling of distance) in a room of 100
# m^3 with reverberation time 0.6 s and background noise of 45 dB. The
# critical distance, where direct and reverberant sound are equal, is
# 0.057 sqrt(Q V / T) with directivity Q = 2. Shown: direct level,
# direct-to-reverberant ratio (D/R) and signal-to-noise ratio (SNR). The
# rule of thumb used in this book: D/R of at least 10 dB and SNR of at
# least 30 dB for perturbation measures.
from math import log10, sqrt

V, T60, Q, NOISE = 100.0, 0.6, 2.0, 45.0

if __name__ == "__main__":
    rc = 0.057 * sqrt(Q * V / T60)
    print("   critical distance {:.2f} m".format(rc))
    print("   distance (m)  direct (dB)  D/R (dB)  SNR (dB)  usable")
    for r in (0.05, 0.1, 0.2, 0.3, 0.5, 1.0, 2.0):
        lvl = 70 - 20 * log10(r / 0.3)
        dr = 20 * log10(rc / r)
        snr = lvl - NOISE
        print("   {:12.2f}  {:11.1f}  {:8.1f}  {:8.1f}  {:>6}".format(
            r, lvl, dr, snr, "yes" if dr >= 10 and snr >= 30 else "no"))
#    critical distance 1.04 m
#    distance (m)  direct (dB)  D/R (dB)  SNR (dB)  usable
#            0.05         85.6      26.4      40.6     yes
#            0.10         79.5      20.3      34.5     yes
#            0.20         73.5      14.3      28.5      no
#            0.30         70.0      10.8      25.0      no
#            0.50         65.6       6.4      20.6      no
#            1.00         59.5       0.3      14.5      no
#            2.00         53.5      -5.7       8.5      no

The critical distance is 1.04 m; at 1 m the direct and reverberant sound are equal. With this book’s rule of thumb (direct-to-reverberant ratio of at least 10 dB and signal-to-noise ratio of at least 30 dB), only distances of 0.05 and 0.10 m qualify; at 0.3 m the signal-to-noise ratio is 25.0 dB. A headset microphone at a fixed distance is the practical answer.

How many days make a baseline

p16 turns the day-to-day variation of p14 into the number of recording days needed for a personal baseline of a given precision.

Calculation

# Chapter 8. p16: How many recording days does a personal baseline need?
# With the day-to-day standard deviations w of p14, the mean of k days
# has a 95% half-width of 1.96 w / sqrt(k). Shown for k = 1 to 20 days,
# and the days needed for a chosen precision.
from math import ceil, sqrt

MEASURES = (("mean F0 (st)", 0.8, 0.5), ("jitter %", 0.12, 0.05),
            ("shimmer %", 0.7, 0.3), ("pause ratio", 0.04, 0.02),
            ("final slope st/s", 6.0, 3.0))

if __name__ == "__main__":
    ks = (1, 3, 5, 10, 20)
    print("   measure           " + "".join("  k={:<4d}".format(k)
                                            for k in ks) + "  target  days")
    for name, w, target in MEASURES:
        row = "".join("  {:6.3f}".format(1.96 * w / sqrt(k)) for k in ks)
        need = ceil((1.96 * w / target) ** 2)
        print("   {:<16}  {}  {:6.2f}  {:4d}".format(name, row, target, need))
#    measure             k=1     k=3     k=5     k=10    k=20    target  days
#    mean F0 (st)         1.568   0.905   0.701   0.496   0.351    0.50    10
#    jitter %             0.235   0.136   0.105   0.074   0.053    0.05    23
#    shimmer %            1.372   0.792   0.614   0.434   0.307    0.30    21
#    pause ratio          0.078   0.045   0.035   0.025   0.018    0.02    16
#    final slope st/s    11.760   6.790   5.259   3.719   2.630    3.00    16

Ten days give mean pitch within half a semitone; jitter within 0.05 percentage points needs 23 days and shimmer within 0.3 points 21; pause ratio within 0.02 and final slope within 3 st/s need 16 days each. A one-session “voice authority score” is therefore mostly day-to-day noise for every measure except pitch.

Hypothesis · not established

The author’s interpretation (not yet tested): a composite voice score averaged over at least ten recording days predicts listeners’ ratings of a speaker’s authority in new recordings better than the same score from a single day. What would show it wrong: in a study with at least ten recording days per speaker and independent listener ratings, the ten-day score correlates no more strongly with the ratings than the single-day score.

Summary

Among the measures of this book only mean pitch is repeatable enough to be read from one session; perturbation, pause and slope measures need many days and a close, fixed microphone. A responsible diagnostic publishes its reliability and asks for repeated recordings.

References

Shrout, Patrick E., and Joseph L. Fleiss. 1979. “Intraclass Correlations: Uses in Assessing Rater Reliability.” Psychological Bulletin 86 (2): 420 to 428.

Fan, Y. (2026). Singer Formant Clustering, Glottal Closure Quotients and Acoustic Authority Psychophysics: Subglottal Pressure Dynamics, Pitch-Floor Stability and Pause-to-Phoneme Persuasion Ratios [歌手共振峰簇、声门闭合商与声学权威度心理物理学] (Version 1.0.0). 5D Library. https://doi.org/10.5281/zenodo.24090258 · Licensed under Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0).