5D Library › Singer Formant Clustering, Glottal Closure Quotients and Acoustic Authority Psychophysics · 中文
Chapter 8. Practice: A Measurement Protocol for an Authority Voice Diagnostic
Note
Not a medical or clinical tool. This chapter outlines how voice measures could be collected for coaching and discussion. Jitter, shimmer and closed quotient are also used in clinical voice assessment; hoarseness lasting more than a few weeks should be examined by a physician. The parameters in this chapter are illustrative.
Which measures are repeatable
A diagnostic that reports one number per person must first show that the number is stable from day to day. p14 uses illustrative between-person and within-person standard deviations to compute reliability (the intraclass correlation (Shrout and Fleiss 1979)) and the smallest detectable change.
Calculation
# Chapter 8. p14: How repeatable are the measures? Illustrative between-
# person and within-person (day-to-day) standard deviations. Reliability
# ICC = b^2 / (b^2 + w^2); the smallest change in one person that is
# larger than day-to-day noise with 95% confidence is MDC = 1.96 *
# sqrt(2) * w. A study of 40 persons measured on two days estimates the
# ICC; its 10% to 90% range over 2,000 such studies is shown. Seed 99.
import random
from math import sqrt
MEASURES = (("mean F0 (st)", 2.5, 0.8), ("jitter %", 0.15, 0.12),
("shimmer %", 0.8, 0.7), ("pause ratio", 0.05, 0.04),
("final slope st/s", 5.0, 6.0))
def icc(pairs):
n = len(pairs)
m = sum(a + b for a, b in pairs) / (2 * n)
msb = 2 * sum(((a + b) / 2 - m) ** 2 for a, b in pairs) / (n - 1)
msw = sum((a - b) ** 2 / 2 for a, b in pairs) / n
return (msb - msw) / (msb + msw)
if __name__ == "__main__":
rng = random.Random(99)
print(" measure ICC MDC study ICC 10% to 90%")
for name, b, w in MEASURES:
est = []
for _ in range(2000):
pairs = []
for _ in range(40):
t = rng.gauss(0, b)
pairs.append((t + rng.gauss(0, w), t + rng.gauss(0, w)))
est.append(icc(pairs))
est.sort()
print(" {:<16} {:5.2f} {:6.2f} {:6.2f} to {:5.2f}".format(
name, b * b / (b * b + w * w), 1.96 * sqrt(2) * w,
est[200], est[1800]))
# measure ICC MDC study ICC 10% to 90%
# mean F0 (st) 0.91 2.22 0.87 to 0.94
# jitter % 0.61 0.33 0.46 to 0.72
# shimmer % 0.57 1.94 0.40 to 0.69
# pause ratio 0.61 0.11 0.47 to 0.72
# final slope st/s 0.41 16.63 0.23 to 0.57Mean pitch is highly repeatable (0.91), with a smallest detectable change of 2.22 semitones. Jitter and pause ratio are moderate (0.61), shimmer lower (0.57), and the final slope poor (0.41): a single day’s slope must change by 16.63 st/s before the change exceeds day-to-day noise. A study of 40 persons estimates these reliabilities with wide ranges (0.23 to 0.57 for the slope), so a diagnostic should publish its own test-retest data.
Where to put the microphone
p15 places a voice of 70 dB at 0.3 m in a typical meeting room.
Calculation
# Chapter 8. p15: Where to put the microphone. A voice of 70 dB at 0.3 m
# (direct sound falls 6 dB per doubling of distance) in a room of 100
# m^3 with reverberation time 0.6 s and background noise of 45 dB. The
# critical distance, where direct and reverberant sound are equal, is
# 0.057 sqrt(Q V / T) with directivity Q = 2. Shown: direct level,
# direct-to-reverberant ratio (D/R) and signal-to-noise ratio (SNR). The
# rule of thumb used in this book: D/R of at least 10 dB and SNR of at
# least 30 dB for perturbation measures.
from math import log10, sqrt
V, T60, Q, NOISE = 100.0, 0.6, 2.0, 45.0
if __name__ == "__main__":
rc = 0.057 * sqrt(Q * V / T60)
print(" critical distance {:.2f} m".format(rc))
print(" distance (m) direct (dB) D/R (dB) SNR (dB) usable")
for r in (0.05, 0.1, 0.2, 0.3, 0.5, 1.0, 2.0):
lvl = 70 - 20 * log10(r / 0.3)
dr = 20 * log10(rc / r)
snr = lvl - NOISE
print(" {:12.2f} {:11.1f} {:8.1f} {:8.1f} {:>6}".format(
r, lvl, dr, snr, "yes" if dr >= 10 and snr >= 30 else "no"))
# critical distance 1.04 m
# distance (m) direct (dB) D/R (dB) SNR (dB) usable
# 0.05 85.6 26.4 40.6 yes
# 0.10 79.5 20.3 34.5 yes
# 0.20 73.5 14.3 28.5 no
# 0.30 70.0 10.8 25.0 no
# 0.50 65.6 6.4 20.6 no
# 1.00 59.5 0.3 14.5 no
# 2.00 53.5 -5.7 8.5 noThe critical distance is 1.04 m; at 1 m the direct and reverberant sound are equal. With this book’s rule of thumb (direct-to-reverberant ratio of at least 10 dB and signal-to-noise ratio of at least 30 dB), only distances of 0.05 and 0.10 m qualify; at 0.3 m the signal-to-noise ratio is 25.0 dB. A headset microphone at a fixed distance is the practical answer.
How many days make a baseline
p16 turns the day-to-day variation of p14 into the number of recording days needed for a personal baseline of a given precision.
Calculation
# Chapter 8. p16: How many recording days does a personal baseline need?
# With the day-to-day standard deviations w of p14, the mean of k days
# has a 95% half-width of 1.96 w / sqrt(k). Shown for k = 1 to 20 days,
# and the days needed for a chosen precision.
from math import ceil, sqrt
MEASURES = (("mean F0 (st)", 0.8, 0.5), ("jitter %", 0.12, 0.05),
("shimmer %", 0.7, 0.3), ("pause ratio", 0.04, 0.02),
("final slope st/s", 6.0, 3.0))
if __name__ == "__main__":
ks = (1, 3, 5, 10, 20)
print(" measure " + "".join(" k={:<4d}".format(k)
for k in ks) + " target days")
for name, w, target in MEASURES:
row = "".join(" {:6.3f}".format(1.96 * w / sqrt(k)) for k in ks)
need = ceil((1.96 * w / target) ** 2)
print(" {:<16} {} {:6.2f} {:4d}".format(name, row, target, need))
# measure k=1 k=3 k=5 k=10 k=20 target days
# mean F0 (st) 1.568 0.905 0.701 0.496 0.351 0.50 10
# jitter % 0.235 0.136 0.105 0.074 0.053 0.05 23
# shimmer % 1.372 0.792 0.614 0.434 0.307 0.30 21
# pause ratio 0.078 0.045 0.035 0.025 0.018 0.02 16
# final slope st/s 11.760 6.790 5.259 3.719 2.630 3.00 16Ten days give mean pitch within half a semitone; jitter within 0.05 percentage points needs 23 days and shimmer within 0.3 points 21; pause ratio within 0.02 and final slope within 3 st/s need 16 days each. A one-session “voice authority score” is therefore mostly day-to-day noise for every measure except pitch.
Hypothesis · not established
The author’s interpretation (not yet tested): a composite voice score averaged over at least ten recording days predicts listeners’ ratings of a speaker’s authority in new recordings better than the same score from a single day. What would show it wrong: in a study with at least ten recording days per speaker and independent listener ratings, the ten-day score correlates no more strongly with the ratings than the single-day score.
Summary
Among the measures of this book only mean pitch is repeatable enough to be read from one session; perturbation, pause and slope measures need many days and a close, fixed microphone. A responsible diagnostic publishes its reliability and asks for repeated recordings.
References
Fan, Y. (2026). Singer Formant Clustering, Glottal Closure Quotients and Acoustic Authority Psychophysics: Subglottal Pressure Dynamics, Pitch-Floor Stability and Pause-to-Phoneme Persuasion Ratios [歌手共振峰簇、声门闭合商与声学权威度心理物理学] (Version 1.0.0). 5D Library. https://doi.org/10.5281/zenodo.24090258 · Licensed under Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0).