What does Overtone Cavities, Liuzijue Impedance and Humming Nitric Oxide conclude, in numbers, about “A Two-Compartment Model of Sinus Nitric Oxide: Peak, Decay and Recovery of the Humming Gain”?
Answer: Chapter 5 uses a two-compartment model of sinus and nose to interpret the published finding that humming raises nasal nitric oxide about fifteen-fold: it is the instantaneous peak of a store being washed out, the second hum peaks at only 0.398 of the first, and recovery to nine tenths takes 13.7 minutes. The joint model of Chapter 6 finds that overtone focus and sinus flux conflict at one tongue gap: the unconstrained optimum is 0.755 millimetres with a gain of 4.48, while requiring focus moves it to 0.296 millimetres and lowers the gain to 3.26; Monte Carlo puts the median share of excess gain given up for focus at 0.373.
Scope of the numbers: Most anatomical sizes, pressures and concentrations are illustrative; all calculations are generated by the book's programs; the book is not medical advice and claims no bodily benefit of any breathing method, singing style or vocal exercise. Marked boxes separate published evidence, runnable Python calculations (20 programs), classical sources and the author's hypotheses.
Data table
The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 0.398, 13.7
| quiet output 4.217 nL/s; G0 0.0242 mL/s | |
| humming G for a 15-fold first peak | 6.58 mL/s |
| sinus washout time constant Vs/G | 4.56 s |
| hum start Cs ppm peak gain mean gain over 5 s | |
| 1 | 9.000 15.00 9.52 |
| 2 | 3.214 5.97 4.05 |
| 3 | 1.356 3.07 2.30 |
| 4 | 0.759 2.13 1.74 |
| second peak / first peak | 0.398 |
| refill time constant Vs/(G0 + k Vs) | 356 s = 5.9 min |
| 90 % refill takes 13.7 min |
Show the full program
# Chapter 5. p52: Two-compartment model of nasal NO output. Compartment 1:
# both maxillary sinuses, Vs = 30 mL, producing NO at Ps; compartment 2:
# the nasal airway, whose mucosa adds Pn = 4 nL/s and whose air is swept
# out by the exhaled flow. Sinus-to-nose exchange is G: in quiet breathing
# G0 = ostial diffusion (2 ostia as in p51); during humming G is raised.
# NO is also lost inside the sinus at rate k = 0.002 per s (uptake):
# dCs/dt = (Ps - (G + k Vs) Cs) / Vs, output = Pn + G * Cs (nL/s)
# Resting Cs0 = 9 ppm sets Ps = (G0 + k Vs) Cs0. G for humming is
# calibrated so the first peak is 15 times quiet output, the size
# reported by Weitzberg and Lundberg (2002). Euler steps of 1 ms.
# Pre-registered test: second peak / first peak below 0.8 after 10 s.
import math
VS, PN, CS0, K = 30.0, 4.0, 9.0, 0.002 # mL, nL/s, ppm, 1/s
A = math.pi * 2.5e-3 ** 2 / 4
G0 = 2 * 2e-5 * A / (6e-3 + 1.7 * 1.25e-3) * 1e6 # mL/s
PS = (G0 + K * VS) * CS0
QUIET = PN + G0 * CS0
GH = (15 * QUIET - PN) / CS0
print("quiet output {:.3f} nL/s; G0 {:.4f} mL/s".format(QUIET, G0))
print("humming G for a 15-fold first peak: {:.2f} mL/s".format(GH))
print("sinus washout time constant Vs/G: {:.2f} s".format(VS / GH))
cs, t, dt = CS0, 0.0, 0.001
print(" hum start Cs ppm peak gain mean gain over 5 s")
peaks = []
for k in range(1, 5):
start, acc, n = cs, [], int(5 / dt)
for _ in range(n):
acc.append((PN + GH * cs) / QUIET)
cs += dt * (PS - (GH + K * VS) * cs) / VS
print(" {:d} {:6.3f} {:6.2f} {:6.2f}".format(
k, start, acc[0], math.fsum(acc) / n))
peaks.append(acc[0])
for _ in range(int(10 / dt)):
cs += dt * (PS - (G0 + K * VS) * cs) / VS
print("second peak / first peak: {:.3f}".format(peaks[1] / peaks[0]))
tau = VS / (G0 + K * VS)
print("refill time constant Vs/(G0 + k Vs) = {:.0f} s = {:.1f} min".format(
tau, tau / 60))
print("90 % refill takes {:.1f} min".format(tau * math.log(10) / 60))Single source and citation
Fan, Y. (2026). Two-Cavity Vocal-Tract Coupling in Overtone Singing, Airflow Impedance Spectra of the Liuzijue Six Sounds and Oscillatory Gain in Exhaled Nitric Oxide (Version 1.0.0), Chapter 5: A Two-Compartment Model of Sinus Nitric Oxide: Peak, Decay and Recovery of the Humming Gain. 5D Library. DOI pending
DOI pending · monograph page goes live after publication · 5DL-B-160 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026160,
author = {Fan, Yafu},
title = {Two-Cavity Vocal-Tract Coupling in Overtone Singing, Airflow Impedance Spectra of the Liuzijue Six Sounds and Oscillatory Gain in Exhaled Nitric Oxide},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
note = {DOI pending}
}Other chapter answers in this book
- Chapter 1 · Two Tubes and Two Helmholtz Cavities: Vocal-Tract Resonances and Coupling Splits
- Chapter 2 · Source, Filter and Overtone Focus: the Gain of Every Harmonic
- Chapter 3 · Airflow Impedance Spectra of the Six Liuzijue Mouth Shapes: Bernoulli, Poiseuille and Exhalation Time
- Chapter 4 · Positive Pressure behind the Tongue Tip: Pressure Division, Transglottal Pressure and Nasal Diversion
- Chapter 6 · One Gap, Three Consequences: a Joint Model of Overtone Focus and Sinus Flux
- Chapter 7 · The Classics Examined: the Six Exhalations of the *Yangxing yanming lu* and Helmholtz's Resonators
- Chapter 8 · Practice and Falsification: an Operator's Checklist, a Copy Checker and a Pre-Registered Test