What does Rhythmic Sound, ASSR and Modulation conclude, in numbers, about “Auditory Steady-State Responses and the Arnold Tongue”?
Answer: Chapter 2 draws the Arnold tongue of Adler's equation and computes how the signal-to-noise ratio of the auditory steady-state response grows with recording time: a 40 Hz isochronic tone becomes visible in 8.0 s, a binaural beat at the same rate needs 7.8 min, 58.1 times longer, and a static tone has drive 0.
Scope of the numbers: Its phase-locking curves, response amplitudes, EEG noise and arousal probabilities are illustrative model parameters, not data from any listener or product; it gives no medical, hearing-care or sleep-treatment advice. Under an illustrative phase-locking curve, an isochronic tone drives 17.6 dB more power than a binaural beat on a 400 Hz carrier and 84.4 dB more at 2,000 Hz.
Data table
The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 40, 58.1, 7.8, 8.0
| rate Hz a (uV) isochronic T binaural T ratio | |
| 0.1 | 0.150 9.9 h 574.1 h 58.1 |
| 2.0 | 0.150 29.6 m 28.7 h 58.1 |
| 6.0 | 0.150 9.9 m 9.6 h 58.1 |
| 10.0 | 0.150 5.9 m 5.7 h 58.1 |
| 40.0 | 0.500 8.0 s 7.8 m 58.1 |
| amplitude SNR at 40 Hz, isochronic, as T grows: | |
| T | 1 s power 1.25 amplitude 1.12 |
| T | 4 s power 5.00 amplitude 2.24 |
| T | 16 s power 20.00 amplitude 4.47 |
| T | 64 s power 80.00 amplitude 8.94 |
| static tones: modulation depth 0, so drive 0 and a | |
| response of 0 uV at every rate and every duration. | |
| 432 Hz: wavelength 0.794 m in air, 3.426 m in water, | |
| 1.71 billion times the 2 nm width of DNA | |
| 528 Hz: wavelength 0.650 m in air, 2.803 m in water, | |
| 1.40 billion times the 2 nm width of DNA | |
| chance PLV for M random-phase epochs, sqrt(pi / (4 M)): | |
| M | 10 0.2802 |
| M | 40 0.1401 |
| M | 160 0.0701 |
| M | 640 0.0350 |
Show the full program
# Chapter 2. p04: How long must a rhythm play before EEG can see it?
# Illustrative model of an auditory steady-state response (ASSR):
# response amplitude a(fm) = 0.15 + 0.35 exp(-((fm - 40) / 10)^2) uV
# for a fully modulated (isochronic) drive, scaled by the drive;
# background EEG power density P(f) = 4 / f uV^2/Hz (a 1/f law).
# A DFT of T seconds puts the response in one bin of width 1/T, so the
# power SNR is (a^2 / 2) T / P(fm): it grows in proportion to T and the
# amplitude SNR as sqrt(T). We ask for 10 dB and also for at least ten
# full cycles. Binaural drive = 0.13116 (carrier 400 Hz, from p02).
# Then: the drive of a static tone, wavelengths of 432 and 528 Hz,
# and the chance level of the phase locking value over M epochs.
import math
def amp(fm):
return 0.15 + 0.35 * math.exp(-((fm - 40.0) / 10.0) ** 2)
def t_needed(fm, drive, target_db=10.0):
a = amp(fm) * drive
snr_per_s = (a * a / 2.0) / (4.0 / fm)
t_snr = 10 ** (target_db / 10.0) / snr_per_s
return max(t_snr, 10.0 / fm)
def fmt(t):
if t < 60:
return "{:8.1f} s".format(t)
if t < 3600:
return "{:8.1f} m".format(t / 60)
return "{:8.1f} h".format(t / 3600)
if __name__ == "__main__":
print(" rate Hz a (uV) isochronic T binaural T ratio")
for fm in (0.1, 2.0, 6.0, 10.0, 40.0):
ti, tb = t_needed(fm, 1.0), t_needed(fm, 0.13116)
print(" {:7.1f} {:8.3f} {} {} {:6.1f}".format(
fm, amp(fm), fmt(ti), fmt(tb), tb / ti))
print("\n amplitude SNR at 40 Hz, isochronic, as T grows:")
for T in (1, 4, 16, 64):
s = (amp(40) ** 2 / 2) * T / (4.0 / 40)
print(" T = {:3d} s power {:7.2f} amplitude {:6.2f}".format(
T, s, math.sqrt(s)))
print("\n static tones: modulation depth 0, so drive 0 and a")
print(" response of 0 uV at every rate and every duration.")
for f in (432, 528):
print(" {} Hz: wavelength {:.3f} m in air, {:.3f} m in water,"
.format(f, 343.0 / f, 1480.0 / f))
print(" {:.2f} billion times the 2 nm width of DNA"
.format(1480.0 / f / 2e-9 / 1e9))
print("\n chance PLV for M random-phase epochs, sqrt(pi / (4 M)):")
for M in (10, 40, 160, 640):
print(" M = {:4d} {:.4f}".format(M, math.sqrt(math.pi / 4 / M)))Single source and citation
Fan, Y. (2026). Rhythmic Acoustic Stimulation, Auditory Steady-State Responses and Modulation Signal Engineering (Version 1.0.0), Chapter 2: Auditory Steady-State Responses and the Arnold Tongue. 5D Library. https://doi.org/10.5281/zenodo.24090211
DOI: 10.5281/zenodo.24090211 · Read the monograph · 5DL-B-080 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026080,
author = {Fan, Yafu},
title = {Rhythmic Acoustic Stimulation, Auditory Steady-State Responses and Modulation Signal Engineering},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
doi = {10.5281/zenodo.24090211},
url = {https://doi.org/10.5281/zenodo.24090211}
}Other chapter answers in this book
- Chapter 1 · Where Is the Envelope? Binaural Beats and Isochronic Tones
- Chapter 3 · Pink Noise, A-Weighting and Sleep Masking
- Chapter 4 · Delivery Routes and Gating Shapes
- Chapter 5 · Hearing Dose and the Schumann Resonance
- Chapter 6 · Evidence: Detection Power, Placebo and Forking Paths
- Chapter 7 · Pitch Pipes, Sixteen Pitches, the Exact Root and Combination Tones
- Chapter 8 · A Ten-Flag Audit and a Pre-Registered Crossover Trial