What does Singing-Bowl Shell Modes and Touch Thresholds conclude, in numbers, about “The Palm: the Pacinian U-Shaped Threshold, the Meissner Channel and the Spectral Truth About Beats”?

Answer: Chapter 6 shows that (2,0) falls in the most sensitive band of the Pacinian channel and is still 34.6 dB above threshold at a palm under the base; the component at the beat frequency is only 0.0008 microns of numerical leakage, the swell felt is the envelope of the carrier, and one strike is felt for about 22.7 s.

Scope of the numbers: Chapter 1 derives the ring ratio n(n² − 1)/√(n² + 1) from the Rayleigh quotient: (3,0) lies 2.828 times above (2,0), exactly an octave and a tritone, and the (2,0) mode of the illustrative bowl is at 207.6 Hz. Chapter 2 shows that only the 2n-th thickness harmonic splits mode n at first order, that the beat rate equals the split (illustratively 1.25 Hz), and that the depth of the beat depends on where the bowl is struck relative to the mode axes.

中文版

Data table

The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 0.0008, 20, 22.7

test f (Hz)amplitude (um)
1.250.0008
2.500.0008
30.000.0008
207.602.8602
208.852.8602
416.450.0006
envelope: max 5.72 um, min 0.0000 um
palm Q = 3713, tau = 5.69 s
(2,0) at palm stays above P threshold for 22.7 s
same if the threshold were one third: 28.9 s
Show the full program
# Chapter 6. p63: does a 1.25 Hz beat put 1.25 Hz motion into the skin?
# Palm signal: two partials at 207.6 and 208.85 Hz, 2.86 um each (half of
# the 5.721 um of p62), sampled at 2000 Hz for 8 s (10 beat periods).
# A discrete Fourier sum at each test frequency gives the amplitude of
# that component. Then: how long the (2,0) motion at the palm stays above
# the P threshold of p61 with the palm-damped Q of p42.
import math

FS, T = 2000, 8.0
F1, F2, A = 207.6, 208.85, 2.86
NS = int(FS * T)
sig = [A * (math.cos(2 * math.pi * F1 * i / FS)
            + math.cos(2 * math.pi * F2 * i / FS)) for i in range(NS)]


def comp(f):
    c = math.fsum(x * math.cos(2 * math.pi * f * i / FS)
                  for i, x in enumerate(sig))
    s = math.fsum(x * math.sin(2 * math.pi * f * i / FS)
                  for i, x in enumerate(sig))
    return 2 * math.hypot(c, s) / NS


print("test f (Hz)  amplitude (um)")
for f in (1.25, 2.5, 30.0, 207.6, 208.85, 416.45):
    print("{:11.2f}  {:14.4f}".format(f, comp(f)))
env = [abs(2 * A * math.cos(math.pi * (F2 - F1) * i / FS))
       for i in range(0, NS, 8)]
print("envelope: max {:.2f} um, min {:.4f} um".format(max(env), min(env)))


def p_ch(f):
    return 0.1 * ((250 / f) ** 2 + (f / 250) ** 2) / 2


q = 1 / (1 / 4000 + math.tan(math.radians(10)) ** 4 / 50)
tau = q / (math.pi * F1)
t_above = tau * math.log(5.721 / p_ch(F1))
print("palm Q = {:.0f}, tau = {:.2f} s".format(q, tau))
print("(2,0) at palm stays above P threshold for {:.1f} s".format(t_above))
print("same if the threshold were one third: {:.1f} s".format(
    tau * math.log(5.721 / (p_ch(F1) / 3))))

Single source and citation

Fan, Y. (2026). Rayleigh Thin-Shell Modes of Bronze Singing Bowls, Nonlinear Strike Beat Envelopes and Coupling to Somatic Mechanoreceptors (Version 1.0.0), Chapter 6: The Palm: the Pacinian U-Shaped Threshold, the Meissner Channel and the Spectral Truth About Beats. 5D Library. DOI pending

DOI pending · monograph page goes live after publication · 5DL-B-161 · v1.0.0 · CC-BY-NC-ND-4.0

BibTeX
@book{fan2026161,
  author    = {Fan, Yafu},
  title     = {Rayleigh Thin-Shell Modes of Bronze Singing Bowls, Nonlinear Strike Beat Envelopes and Coupling to Somatic Mechanoreceptors},
  year      = {2026},
  publisher = {5D Library},
  edition   = {1.0.0},
  note      = {DOI pending}
}

Other chapter answers in this book