What does In-Ear Noise Cancelling, Occlusion and Listening Effort conclude, in numbers, about “The Occlusion Effect: Lumped Equations of a Closed Ear Canal and the Price of a Vent”?

Answer: Chapter 4 computes the occlusion effect with a lumped model, 13.0 dB at 250 Hz for a shallow fit with a foam leak, and shows that the band in which a vent relieves boom is the band in which it gives up low-frequency isolation.

Scope of the numbers: Chapter 3 checks Bode's sensitivity integral numerically: the quiet side and the loud side of an illustrative feedback loop are each 32.9 dB·kHz. Chapter 5 prices cancellation with the Speech Intelligibility Index: one decibel at 250 Hz is worth only 0.00206 and one at 2000 Hz 0.00883, and in the illustrative scene cancellation lowers the playback level needed for equal intelligibility by 5.1 dB.

中文版

Data table

The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 13.0, 250

source U: open 11.5, shallow 7.5, deep 1.00
occlusion effect in dB6312525050010002000
shallow 4 mm, sealed59.647.735.623.29.8-13.1
shallow 4 mm, foam leak24.318.513.08.87.8-7.0
deep 15 mm, sealed45.433.521.49.0-4.4-27.2
deep 15 mm, foam leak6.81.0-4.5-8.9-11.0-17.6
sealed shallow: open-mass x residual-compliance f0 = 2414 Hz
sealed shallow slope 125 to 250 Hz: 12.12 dB per octave

Key formula

\[\mathrm{OE}(f)\approx 20\log_{10}\frac{U_{\mathrm{occ}}}{U_{\mathrm{open}}}\cdot\frac{1}{\omega^{2}MC}.\]
Show the full program
# Chapter 4. p41: Occlusion effect from a lumped ear-canal model.
# Model (all values illustrative, of textbook order): air 1.204 kg/m^3,
# c = 343 m/s, canal 25 mm long, 7.5 mm wide; outer 10 mm cartilaginous,
# inner 15 mm bony; eardrum load = 0.6 cm^3 of equivalent volume. Bone-
# conducted own voice drives the canal walls as a volume-velocity source
# U, 1 per mm of exposed cartilage and 0.1 per mm of exposed bone.
# Open ear: U sees the canal air mass to the outside, M = rho l / A
# (half the canal plus an end correction 0.61 r), in parallel with the
# compliance C = V / (rho c^2). Occluded: U sees the residual volume,
# in parallel with a foam-like leak, R = 4e6 Pa s/m^3 in series with a
# mass of 1e3 kg/m^4. OE(f) = 20 log10 |U_occ Z_occ| / |U_open Z_open|.
# Sealed and lossless, OE ~ 20 log10 (U_occ / U_open / (w^2 M C)), which
# falls 40 dB a decade; the leak flattens it at low frequency.
import math

RHO, C0 = 1.204, 343.0
LC, LCART, R = 25e-3, 10e-3, 3.75e-3
AREA = math.pi * R * R
V_ED = 0.6e-6
S_CART, S_BONE = 1.0, 0.1
R_LEAK, M_LEAK = 4e6, 1e3


def source(depth):
    cart = max(LCART - depth, 0.0)
    bone = LC - max(depth, LCART)
    return (S_CART * cart + S_BONE * bone) * 1e3


def par(z1, z2):
    return z1 * z2 / (z1 + z2)


def z_open(f):
    w = 2 * math.pi * f
    m = RHO * (LC / 2 + 0.61 * R) / AREA
    cpl = (AREA * LC + V_ED) / (RHO * C0 * C0)
    return par(1j * w * m, 1 / (1j * w * cpl))


def z_occ(f, depth, leak):
    w = 2 * math.pi * f
    cpl = (AREA * (LC - depth) + V_ED) / (RHO * C0 * C0)
    zc = 1 / (1j * w * cpl)
    if not leak:
        return zc
    return par(zc, R_LEAK + 1j * w * M_LEAK)


def oe(f, depth, leak):
    num = source(depth) * abs(z_occ(f, depth, leak))
    return 20 * math.log10(num / (source(0.0) * abs(z_open(f))))


if __name__ == "__main__":
    cases = (("shallow 4 mm, sealed", 4e-3, False),
             ("shallow 4 mm, foam leak", 4e-3, True),
             ("deep 15 mm, sealed", 15e-3, False),
             ("deep 15 mm, foam leak", 15e-3, True))
    freqs = (63, 125, 250, 500, 1000, 2000)
    print("source U: open {:.1f}, shallow {:.1f}, deep {:.2f}".format(
        source(0.0), source(4e-3), source(15e-3)))
    print("occlusion effect in dB" + " " * 9 + "".join(
        "{:>7}".format(f) for f in freqs))
    for name, dep, lr in cases:
        print("{:<30}".format(name) + "".join(
            "{:>7.1f}".format(oe(f, dep, lr)) for f in freqs))
    m = RHO * (LC / 2 + 0.61 * R) / AREA
    cpl = (AREA * (LC - 4e-3) + V_ED) / (RHO * C0 * C0)
    f0 = 1 / (2 * math.pi * math.sqrt(m * cpl))
    print("sealed shallow: open-mass x residual-compliance f0 = "
          "{:.0f} Hz".format(f0))
    print("sealed shallow slope 125 to 250 Hz: {:.2f} dB per octave".format(
        oe(125, 4e-3, False) - oe(250, 4e-3, False)))

Single source and citation

Fan, Y. (2026). LMS Adaptive Filtering in In-Ear Active Noise Cancellation, Occlusion-Effect Bone-Conduction Gain and SNR-Driven Cognitive Recovery (Version 1.0.0), Chapter 4: The Occlusion Effect: Lumped Equations of a Closed Ear Canal and the Price of a Vent. 5D Library. DOI pending

DOI pending · monograph page goes live after publication · 5DL-B-164 · v1.0.0 · CC-BY-NC-ND-4.0

BibTeX
@book{fan2026164,
  author    = {Fan, Yafu},
  title     = {LMS Adaptive Filtering in In-Ear Active Noise Cancellation, Occlusion-Effect Bone-Conduction Gain and SNR-Driven Cognitive Recovery},
  year      = {2026},
  publisher = {5D Library},
  edition   = {1.0.0},
  note      = {DOI pending}
}

Other chapter answers in this book