What does In-Ear Noise Cancelling, Occlusion and Listening Effort conclude, in numbers, about “The Occlusion Effect: Lumped Equations of a Closed Ear Canal and the Price of a Vent”?
Answer: Chapter 4 computes the occlusion effect with a lumped model, 13.0 dB at 250 Hz for a shallow fit with a foam leak, and shows that the band in which a vent relieves boom is the band in which it gives up low-frequency isolation.
Scope of the numbers: Chapter 3 checks Bode's sensitivity integral numerically: the quiet side and the loud side of an illustrative feedback loop are each 32.9 dB·kHz. Chapter 5 prices cancellation with the Speech Intelligibility Index: one decibel at 250 Hz is worth only 0.00206 and one at 2000 Hz 0.00883, and in the illustrative scene cancellation lowers the playback level needed for equal intelligibility by 5.1 dB.
Data table
The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 13.0, 250
| source U: open 11.5, shallow 7.5, deep 1.00 | ||||||
| occlusion effect in dB | 63 | 125 | 250 | 500 | 1000 | 2000 |
| shallow 4 mm, sealed | 59.6 | 47.7 | 35.6 | 23.2 | 9.8 | -13.1 |
| shallow 4 mm, foam leak | 24.3 | 18.5 | 13.0 | 8.8 | 7.8 | -7.0 |
| deep 15 mm, sealed | 45.4 | 33.5 | 21.4 | 9.0 | -4.4 | -27.2 |
| deep 15 mm, foam leak | 6.8 | 1.0 | -4.5 | -8.9 | -11.0 | -17.6 |
| sealed shallow: open-mass x residual-compliance f0 = 2414 Hz | ||||||
| sealed shallow slope 125 to 250 Hz: 12.12 dB per octave |
Key formula
Show the full program
# Chapter 4. p41: Occlusion effect from a lumped ear-canal model.
# Model (all values illustrative, of textbook order): air 1.204 kg/m^3,
# c = 343 m/s, canal 25 mm long, 7.5 mm wide; outer 10 mm cartilaginous,
# inner 15 mm bony; eardrum load = 0.6 cm^3 of equivalent volume. Bone-
# conducted own voice drives the canal walls as a volume-velocity source
# U, 1 per mm of exposed cartilage and 0.1 per mm of exposed bone.
# Open ear: U sees the canal air mass to the outside, M = rho l / A
# (half the canal plus an end correction 0.61 r), in parallel with the
# compliance C = V / (rho c^2). Occluded: U sees the residual volume,
# in parallel with a foam-like leak, R = 4e6 Pa s/m^3 in series with a
# mass of 1e3 kg/m^4. OE(f) = 20 log10 |U_occ Z_occ| / |U_open Z_open|.
# Sealed and lossless, OE ~ 20 log10 (U_occ / U_open / (w^2 M C)), which
# falls 40 dB a decade; the leak flattens it at low frequency.
import math
RHO, C0 = 1.204, 343.0
LC, LCART, R = 25e-3, 10e-3, 3.75e-3
AREA = math.pi * R * R
V_ED = 0.6e-6
S_CART, S_BONE = 1.0, 0.1
R_LEAK, M_LEAK = 4e6, 1e3
def source(depth):
cart = max(LCART - depth, 0.0)
bone = LC - max(depth, LCART)
return (S_CART * cart + S_BONE * bone) * 1e3
def par(z1, z2):
return z1 * z2 / (z1 + z2)
def z_open(f):
w = 2 * math.pi * f
m = RHO * (LC / 2 + 0.61 * R) / AREA
cpl = (AREA * LC + V_ED) / (RHO * C0 * C0)
return par(1j * w * m, 1 / (1j * w * cpl))
def z_occ(f, depth, leak):
w = 2 * math.pi * f
cpl = (AREA * (LC - depth) + V_ED) / (RHO * C0 * C0)
zc = 1 / (1j * w * cpl)
if not leak:
return zc
return par(zc, R_LEAK + 1j * w * M_LEAK)
def oe(f, depth, leak):
num = source(depth) * abs(z_occ(f, depth, leak))
return 20 * math.log10(num / (source(0.0) * abs(z_open(f))))
if __name__ == "__main__":
cases = (("shallow 4 mm, sealed", 4e-3, False),
("shallow 4 mm, foam leak", 4e-3, True),
("deep 15 mm, sealed", 15e-3, False),
("deep 15 mm, foam leak", 15e-3, True))
freqs = (63, 125, 250, 500, 1000, 2000)
print("source U: open {:.1f}, shallow {:.1f}, deep {:.2f}".format(
source(0.0), source(4e-3), source(15e-3)))
print("occlusion effect in dB" + " " * 9 + "".join(
"{:>7}".format(f) for f in freqs))
for name, dep, lr in cases:
print("{:<30}".format(name) + "".join(
"{:>7.1f}".format(oe(f, dep, lr)) for f in freqs))
m = RHO * (LC / 2 + 0.61 * R) / AREA
cpl = (AREA * (LC - 4e-3) + V_ED) / (RHO * C0 * C0)
f0 = 1 / (2 * math.pi * math.sqrt(m * cpl))
print("sealed shallow: open-mass x residual-compliance f0 = "
"{:.0f} Hz".format(f0))
print("sealed shallow slope 125 to 250 Hz: {:.2f} dB per octave".format(
oe(125, 4e-3, False) - oe(250, 4e-3, False)))Single source and citation
Fan, Y. (2026). LMS Adaptive Filtering in In-Ear Active Noise Cancellation, Occlusion-Effect Bone-Conduction Gain and SNR-Driven Cognitive Recovery (Version 1.0.0), Chapter 4: The Occlusion Effect: Lumped Equations of a Closed Ear Canal and the Price of a Vent. 5D Library. DOI pending
DOI pending · monograph page goes live after publication · 5DL-B-164 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026164,
author = {Fan, Yafu},
title = {LMS Adaptive Filtering in In-Ear Active Noise Cancellation, Occlusion-Effect Bone-Conduction Gain and SNR-Driven Cognitive Recovery},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
note = {DOI pending}
}Other chapter answers in this book
- Chapter 1 · LMS and Filtered-x LMS: Where the Step-Size Bound 2/(L·P) Really Sits
- Chapter 2 · Secondary-Path Delay: Phase Error 2πfτ and the Band Edge of 10 dB Cancellation
- Chapter 3 · The Waterbed of Feedback Cancellation: a Numerical Ledger of Bode's Sensitivity Integral
- Chapter 5 · An Exchange Rate for Signal-to-Noise: Pricing Cancellation with the Speech Intelligibility Index
- Chapter 6 · Listening Effort: Kahneman's Capacity Model and the Inverted U of the Pupil
- Chapter 7 · Sources Examined: "The Great Sound Is Faint" and Lueg's Duct
- Chapter 8 · Practice and Refutation: a Persuasive-Copy Checker and Pre-Registered Tests