What does Ear Afference and the Gain Bounds of Slow Breathing conclude, in numbers, about “Four In, Eight Out: Detuning, Harmonics and Phase Locking at Five a Minute”?
Answer: Chapter 4 finds that four in and eight out gives 0.818 of the heart-rate swing of five in and five out in the illustrative loop, and separates a linear from a nonlinear reading of "phase locking".
Scope of the numbers: Loop parameters, skin moduli and population ranges are illustrative; all calculations are generated by the book's programs; the book is not medical advice and claims no bodily benefit for ear pressing, ear stimulation, breathing exercises or sound products. Chapter 4 finds that four in and eight out gives 0.818 of the heart-rate swing of five in and five out in the illustrative loop, and separates a linear from a nonlinear reading of "phase locking".
Data table
The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 0.818
| pattern | /min | h1 | h2 | h3 | HR swing | peak s | fall share |
| 5 in / 5 out | 6.0 | 0.50 | 0.00 | 0.00 | 1.000 | 6.61 | 0.678 |
| 4 in / 8 out | 5.0 | 0.49 | 0.09 | 0.03 | 0.818 | 5.44 | 0.762 |
| 6 in / 6 out | 5.0 | 0.50 | 0.00 | 0.00 | 0.839 | 6.54 | 0.910 |
| 4 in / 6 out | 6.0 | 0.50 | 0.06 | 0.01 | 0.993 | 6.06 | 0.657 |
| 3 in / 9 out | 5.0 | 0.48 | 0.12 | 0.06 | 0.794 | 4.91 | 0.676 |
| 2 in / 3 out | 12.0 | 0.50 | 0.06 | 0.01 | 0.208 | 3.58 | 0.473 |
Show the full program
# Chapter 4. p41: Four in, eight out, against the resonance of the loop.
# Lung volume rises as a half cosine over the inhale Ti and falls as a
# half cosine over the exhale Te (peak-to-trough 1). Its Fourier series
# (2400 samples a cycle, 10 harmonics) is passed through the central
# closed loop of p31, H = P / (1 + L), read here as heart-rate rise per
# unit volume. Columns: harmonic shares of the volume swing, the heart
# rate swing relative to the 5 s / 5 s pattern, the time of the heart
# rate peak after inhale onset, and the share of the exhale during which
# heart rate is falling. All loop parameters are illustrative.
import cmath
import math
FC, D, KL, TAU, T = 0.12, 0.5, 0.8, 3.8, 1.5
N, NH = 2400, 10
def H(f):
w = 2 * math.pi * f
p = cmath.exp(-1j * w * D) / (1 + 1j * f / FC)
return p / (1 + KL * cmath.exp(-1j * w * TAU) / (1 + 1j * w * T))
def volume(t, ti, te):
if t < ti:
return (1 - math.cos(math.pi * t / ti)) / 2
return (1 + math.cos(math.pi * (t - ti) / te)) / 2
def response(ti, te):
tc = ti + te
ts = [tc * i / N for i in range(N)]
v = [volume(t, ti, te) for t in ts]
coef = []
for n in range(1, NH + 1):
c = math.fsum(v[i] * math.cos(2 * math.pi * n * i / N)
for i in range(N)) / N
s = math.fsum(v[i] * math.sin(2 * math.pi * n * i / N)
for i in range(N)) / N
coef.append(complex(c, -s))
y = []
for t in ts:
terms = [2 * (coef[n - 1] * H(n / tc)
* cmath.exp(2j * math.pi * n * t / tc)).real
for n in range(1, NH + 1)]
y.append(math.fsum(terms))
harm = [2 * abs(c) for c in coef[:3]]
ip = y.index(max(y))
falling = len([i for i in range(N) if ts[i] >= ti
and y[(i + 1) % N] < y[i]])
n_ex = len([t for t in ts if t >= ti])
return harm, max(y) - min(y), ts[ip], falling / n_ex
PATTERNS = (("5 in / 5 out", 5, 5), ("4 in / 8 out", 4, 8),
("6 in / 6 out", 6, 6), ("4 in / 6 out", 4, 6),
("3 in / 9 out", 3, 9), ("2 in / 3 out", 2, 3))
ref = response(5, 5)[1]
print(" pattern /min h1 h2 h3 HR swing peak s"
" fall share")
for name, ti, te in PATTERNS:
harm, sw, tp, fall = response(ti, te)
print(" {:12s} {:5.1f} {:4.2f} {:4.2f} {:4.2f} {:5.3f} {:5.2f}"
" {:5.3f}".format(name, 60.0 / (ti + te), harm[0], harm[1],
harm[2], sw / ref, tp, fall))Single source and citation
Fan, Y. (2026). Ear-Canal Pressure and Vagal Afference, Exhale-Prolonged Phase Locking and Gain Bounds of the Slow-Wave Baroreflex (Version 1.0.0), Chapter 4: Four In, Eight Out: Detuning, Harmonics and Phase Locking at Five a Minute. 5D Library. DOI pending
DOI pending · monograph page goes live after publication · 5DL-B-162 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026162,
author = {Fan, Yafu},
title = {Ear-Canal Pressure and Vagal Afference, Exhale-Prolonged Phase Locking and Gain Bounds of the Slow-Wave Baroreflex},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
note = {DOI pending}
}Other chapter answers in this book
- Chapter 1 · A Nerve Map of the Cymba Conchae: Fourteen Ears, Contact Patches and Sound Pressure
- Chapter 2 · Respiratory Sinus Arrhythmia: Heart Rate as a Low-Pass Output of the Breathing Drive
- Chapter 3 · The Delayed Baroreflex Loop: Resonance at Six a Minute and a Ceiling on Gain
- Chapter 5 · Artefacts of the Indices: How RMSSD and LF/HF Follow the Breathing Rate
- Chapter 6 · Effect Sizes of Ear Stimulation: Sham Control, the Winner's Curse and Regression to the Mean
- Chapter 7 · The Classics Examined: Yawning, Sobbing, Sighing and Ringing Ears in the *Lingshu*, Read with Ludwig and Hales
- Chapter 8 · Practice and Refutation: an Operator's Checklist, a Copy Checker and Pre-Registered Tests