What does Massage Oil, Warmth and Return Visits conclude, in numbers, about “Fick's Laws and the Membrane Model: Steady Flux, Lag Time and the Myth of "Going Deeper"”?
Answer: Chapters 1 to 3 correct the project blueprint. Terpenes mix with medium-chain (C8/C10) triglyceride in any proportion, so there is no saturation ceiling; the neat oil has about 18.12 times the activity of a 2 % blend. An illustrative stratum corneum has a lag time of about 62.5 minutes, and doubling the concentration does not push the profile deeper. In a sixty-minute open session 99.994 % of the alpha-pinene evaporates, while zingiberene loses 49.385 % to the air and leaves 0.2445 % in the stratum corneum; raising the blend from 1 % to 10 % moves the share reaching the skin only from 0.2447 % to 0.2583 %.
Scope of the numbers: All concentrations, amounts, vapour pressures, temperatures and rating parameters are illustrative, and every calculation is generated by the book's programs. The book is not medical advice: it claims no effect for any oil, carrier, temperature or technique, gives no recommendation on dose or concentration, and leaves dilution, patch testing and use in pregnancy or with children to qualified professionals.
Data table
The numbers below are printed verbatim by the chapter's Python program and can be reproduced by running it. standard-library Python onlyprinted values that match the answer: 10, 60, 62.5
| slab h | 15 um, D = 1e-10 cm^2/s, grid r = 0.4 |
| lag h^2/6D | 3750.0 s = 62.5 min |
| lag, Crank series | 3750.0 s |
| lag, finite diff. | 3735.8 s |
| steady flux / (D C0 / h), FD at 10 lags | 1.0000 |
| minute J/Jss(FD) J/Jss(series) Q/Q_if_steady_from_t0 | |
| 15 | 0.0106 0.0109 0.0014 |
| 30 | 0.1766 0.1753 0.0401 |
| 60 | 0.5931 0.5913 0.2189 |
| 90 | 0.8140 0.8129 0.3846 |
| 120 | 0.9156 0.9150 0.5061 |
Show the full program
# Chapter 1. p11: membrane lag time, finite differences against Crank
# Fick's second law in a stratum corneum slab of thickness h: constant
# surface concentration at x = 0 (infinite dose), perfect sink at x = h.
# All parameters are illustrative orders of magnitude, not measurements.
import math
H = 15e-4 # slab thickness in cm (15 micrometres, illustrative)
D = 1.0e-10 # diffusivity in the slab, cm^2/s (illustrative)
C0 = 1.0 # surface concentration in the slab, arbitrary units
N = 30 # grid intervals
DX = H / N
DT = 0.4 * DX * DX / D # explicit scheme, r = 0.4 (stable below 0.5)
R = D * DT / (DX * DX)
def crank_q(t):
"""Amount per area through the slab, series solution (Crank 1975)."""
terms = []
for n in range(1, 200):
terms.append(((-1) ** n) / (n * n)
* math.exp(-D * n * n * math.pi ** 2 * t / H ** 2))
return H * C0 * (D * t / H ** 2 - 1.0 / 6.0
- 2.0 / math.pi ** 2 * math.fsum(terms))
def run_fd(t_end):
c = [0.0] * (N + 1)
c[0] = C0
out = [] # amount leaving through the sink in each step
flux = [] # (time, outflow flux)
t = 0.0
while t < t_end - 1e-9:
new = c[:]
for i in range(1, N):
new[i] = c[i] + R * (c[i - 1] - 2.0 * c[i] + c[i + 1])
c = new
t += DT
j = D * c[N - 1] / DX
out.append(j * DT)
flux.append((t, j))
return out, flux
lag = H * H / (6.0 * D)
jss = D * C0 / H
out, flux = run_fd(10.0 * lag)
steps_per_lag = int(round(lag / DT))
q4 = math.fsum(out[:9 * steps_per_lag])
q5 = math.fsum(out[:10 * steps_per_lag])
slope = (q5 - q4) / lag
lag_fd = 10.0 * lag - q5 / slope
c4, c5 = crank_q(9.0 * lag), crank_q(10.0 * lag)
lag_cr = 10.0 * lag - c5 / ((c5 - c4) / lag)
print("slab h = 15 um, D = 1e-10 cm^2/s, grid r = {:.1f}".format(R))
print("lag h^2/6D {:8.1f} s = {:5.1f} min".format(lag, lag / 60))
print("lag, Crank series {:8.1f} s".format(lag_cr))
print("lag, finite diff. {:8.1f} s".format(lag_fd))
print("steady flux / (D C0 / h), FD at 10 lags: {:.4f}".format(
flux[-1][1] / jss))
print("minute J/Jss(FD) J/Jss(series) Q/Q_if_steady_from_t0")
for m in (15, 30, 60, 90, 120):
t = 60.0 * m
k = int(round(t / DT)) - 1
js = []
for n in range(1, 200):
js.append(((-1) ** n)
* math.exp(-D * n * n * math.pi ** 2 * t / H ** 2))
jser = 1.0 + 2.0 * math.fsum(js)
q = crank_q(t)
print("{:5d} {:8.4f} {:12.4f} {:12.4f}".format(
m, flux[k][1] / jss, jser, q / (jss * t)))Single source and citation
Fan, Y. (2026). Fickian Transdermal Diffusion of Botanical Massage Oils, Thermal Comfort Kinetics and Wellness Studio Retention (Version 1.0.0), Chapter 1: Fick's Laws and the Membrane Model: Steady Flux, Lag Time and the Myth of "Going Deeper". 5D Library. DOI pending
DOI pending · monograph page goes live after publication · 5DL-B-339 · v1.0.0 · CC-BY-NC-ND-4.0
BibTeX
@book{fan2026339,
author = {Fan, Yafu},
title = {Fickian Transdermal Diffusion of Botanical Massage Oils, Thermal Comfort Kinetics and Wellness Studio Retention},
year = {2026},
publisher = {5D Library},
edition = {1.0.0},
note = {DOI pending}
}Other chapter answers in this book
- Chapter 2 · Partition Coefficients and Carriers: the Activity of Ginger and Frankincense Constituents in Medium-Chain (C8/C10) Triglyceride
- Chapter 3 · Evaporation from an Open Surface: the Mass Balance of a Massage
- Chapter 4 · First-Order Response of Skin Temperature: Contact Temperature, the Heat Capacity of an Oil Film and a Time-Temperature Red Line
- Chapter 5 · The Comfort Band and Adaptation: an Optimal Temperature Trajectory, Not "the Hotter the Better"
- Chapter 6 · The Peak-End Rule and Repurchase: the Elasticity of the Ending and Retention Curves
- Chapter 7 · Classical Sources: "Massage and Medicated Wine" in the Basic Questions, and Fick in 1855
- Chapter 8 · The Empirical Loop and the Distillation Spec: Service Records, the Calculator and a Refutation after One Quarter