5D Library › Singer Formant Clustering, Glottal Closure Quotients and Acoustic Authority Psychophysics · 中文
Preface: Measuring the Voice That Carries
Note
Please read this first. This book studies three things: what clustering the third to fifth formants does to a voice’s spectrum and to its intelligibility in noise; which acoustic measures (jitter, shimmer, final falls, pauses) can be measured reliably and what they can predict about listeners’ judgments; and what straw phonation can be expected to change in fourteen days. Its acoustic and rating parameters are illustrative or synthetic models, meant to show structure; all calculations are generated by the programs printed in the book. This book is not medical advice, and its measures are not a clinical or diagnostic tool.
Several claims about the authoritative voice are popular: that a speaker’s formant cluster near 3 kHz raises the signal-to-noise ratio by 12 dB in 75 dB of noise without shouting; that jitter below 1%, shimmer below 3%, a falling end to statements and a pause ratio of 18% to 25% carry trust and dominance with known weights; that fourteen days of semi-occluded vocal tract exercises raise the glottal closed quotient along a predictable curve. This book writes them as arithmetic that can be run, then asks when they hold.
What the book covers
Chapter 1 builds a source-filter model and shows what moving F3, F4 and F5 together does to the spectrum. Chapter 2 scores the effect in 75 dB of speech-shaped noise and translates it into subglottal pressure. Chapter 3 computes jitter and shimmer and shows how much the recorder adds. Chapter 4 measures final falls and pause ratios and shows how much each depends on the method. Chapter 5 asks what a regression of trust ratings on voice measures can recover, and whether the best pause ratio can be located. Chapter 6 computes the back pressure of straws and the evidence a fourteen-day training curve would need. Chapter 7 reads the Record of Music, the five tones of the Guanzi and the “Quan” chapter of the Guiguzi. Chapter 8 outlines a measurement protocol.
Claims corrected after checking
- Band gain is not broadband gain. In the model the cluster adds 14.2 dB in the 2 to 4 kHz band (Chapter 1, p01) but is worth 6.7 dB of broadband level for intelligibility in 75 dB of noise (Chapter 2, p03); its real benefit is that the subglottal pressure needed falls from 1.77 to 0.99 kPa (p04).
- Clinical thresholds are not persuasion targets. The often-quoted limits of 1.04% for jitter and 3.81% for shimmer separate healthy from disordered voices; with 50 cycles an ordinary healthy voice crosses one of them in 0.170 of recordings (Chapter 3, p05).
- The recorder adds jitter. A voice with true jitter 0.34% measured 1.00% when sampled at 8 kHz without interpolation (p06).
- A pause ratio needs a definition. The same recordings gave 0.241 or 0.127 depending on the minimum pause duration (Chapter 4, p08); a final-fall slope needs a robust estimator once octave errors occur (p07).
- Regression weights are fragile. In a synthetic study of 120 recordings the weight of jitter was estimated at -0.123 with standard error 0.318 although the true value was -0.30 (Chapter 5, p09); with a flatter optimum, studies of 60 recordings place the best pause ratio inside 0.18 to 0.25 only 0.402 of the time (p10).
- A fourteen-day curve needs a control group. Five persons suffice for a mean gain of 0.06 in closed quotient, but 69 are needed for 0.015 (Chapter 6, p12); straw back pressure is set by the diameter, 474 Pa at 3 mm and 30 Pa at 6 mm (p11).
- The Guiguzi does not say “slow and fast”. Its “Quan” chapter, in the received text, contains neither phrase; it asks the speaker to adapt to the listener (Chapter 7, p13).
How to read the boxes
The boxes separate published evidence, runnable Python computations (16 programs, standard library only, fixed random seeds, each actually run at build time with its real output printed beneath it), classical sources, notes and the author’s hypotheses; every hypothesis states what result would show it wrong. Programs and their output use ASCII characters only.
Disclosure
The author uses the works of 5D Library (including this book) as the methodological basis of community courses, the 5D Ascension Cards (Dimensional Shift Card Decks) and the Yafu AI knowledge base, and runs several websites, paid online calculators, subscriptions, reports, courses, business licences and advisory services, including a voice and speech diagnostic, which is exactly what this book studies; the author therefore has a direct commercial interest in its subject. This book promotes no software, course, card deck, device or service, uses no client’s recordings, and accepts no sponsorship from any company. All parameters in the book are synthetic or illustrative. The hypotheses of Chapters 1 to 8 must be tested under pre-registered protocols, and the results published whether positive or negative.
Fan, Y. (2026). Singer Formant Clustering, Glottal Closure Quotients and Acoustic Authority Psychophysics: Subglottal Pressure Dynamics, Pitch-Floor Stability and Pause-to-Phoneme Persuasion Ratios [歌手共振峰簇、声门闭合商与声学权威度心理物理学] (Version 1.0.0). 5D Library. https://doi.org/10.5281/zenodo.24090258 · Licensed under Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0).